Electric Double Layer Capacitors (Gold Capacitor)
Stacked Coin Type
Series : RG Low temperature assured product
Features
●
Endurance : +85 °C 2000 h
Category temperature range : –40 °C to +85 °C
RoHS compliant
●
●
Recommended applications
●
Backup of data/RTC of base station, electronic meter, and industrial equipment
Specifications
Category temp. range
Maximum operating voltage
Nominal capacitance
–40 °C to +85 °C
ꢀ.6 V.DC
0.22 F
1.0 F, 1.5 F
Capacitance change
Internal resistance
ꢀ0 ꢁ of initial measured value at +20 °C (at –40 °C)
7 times of initial measured value at +20 °C (at –40 °C)
Characteristics at
low temperature
<
After 2000 hours application of maximum operating voltage at +85 °C
Capacitance change
ꢀ0 ꢁ of initial measured value at 20 °C
100 Ω or less (0.22 F)
40 Ω or less (1.0 F, 1.5 F)
Endurance
Shelf life
Internal resistance
After 2000 hours storage at +85 °C without load (voltage)
Capacitance change Capacitance change shall meet the specified limits for Endurance
Internal resistance Internal resistance shall meet the specified limits for Endurance
Dimensions in mm(not to scale)
RG series 0.22(F)
RG series 1.0, 1.5(F)
Terminal : V
Terminal : H
Terminal : V
Terminal : H
Sleeve
Sleeve
5.0 max.
10.5 max.
f19.0 0.ꢀ
5.5 0.5
f19.0 0.ꢀ
20.5 Max.
20.0 0.5
11.5 max.
10.0 0.5
0.2 0.05
–
+
5.0 0.8
1.0 0.1
0.8 0.05
5.0 0.5
0.20 0.05
(1.7)
0.2 0.05
1.0 0.1
0.2 0.05
0.8 0.05
(1.7)
(Unit : mm)
Characteristics list
Maximum
operating Capacitance
voltage
(V.DC)
Min.
packaging
q'ty
Capacitance Internal resistance Recommended
Mass
(Reference value)
(g)
tolerance
(F)
discharge current
(mA)
Parts number
(Initial specified value)
(Ω) at 1 kHz
(F)
(pcs)
0.22
1.0
0.176 to 0.ꢀ96
0.8 to 1.8
50
20
20
ꢀ00 µA or less EECRG0V224( )N
1.0
4.1
4.2
200
100
100
<
<
<
ꢀ.6
1 mA or less
1 mA or less
EECRG0V105( )N
EECRG0V155( )N
1.5
1.2 to 2.7
Do not use reflow soldering. (IR, Atmospherheating methods, etc.) Please refer to the page of “Application guidelines”.
( ) : Please use V or H to indicate terminal type.
The recommended discharge current is a reference value. Please design your equipment(circuit) in consideration of IR dorop.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Jan. 2016