Electronic circuit breaker EBU

EBU-TA2-003-AC230V-B-16A 数据手册

 浏览型号EBU-TA2-003-AC230V-B-16A的Datasheet PDF文件第2页浏览型号EBU-TA2-003-AC230V-B-16A的Datasheet PDF文件第3页浏览型号EBU-TA2-003-AC230V-B-16A的Datasheet PDF文件第4页浏览型号EBU-TA2-003-AC230V-B-16A的Datasheet PDF文件第5页浏览型号EBU-TA2-003-AC230V-B-16A的Datasheet PDF文件第6页 
Electronic circuit breaker EBU  
Description  
The electronic circuit protector type EBU (Electronic Breaker Unit)  
provides selective overcurrent protection in AC 230 V UPS systems.  
It consists of an MCB approved for short circuit interruptions up to  
10 kA and of an add-on electronic circuitry, taking over measuring  
and evaluation tasks. The product is available with the typical MCB  
ratings 4 A, 6 A, 10 A and 16 A with B and C characteristics and is  
directly operated at the output of the corresponding UPS.  
UPS units often do not supply sufficient power in the event of a short  
circuit to trip standard MCBs. The electronic AC circuit breaker can  
individually be adjusted to the UPS unit and will therefore reliably trip  
in the event of a short circuit. Optimal adjustment of the load’s current  
rating allows detection and disconnection of an overload in the load  
circuit. This helps exclude the fatal disconnection of the entire output  
voltage of the UPS unit.  
The Electronic Breaker Unit EBU allows a reduction in size of one  
third for UPS units because power reserves do no longer have to  
be kept available for tripping. The EBU increases system availability,  
reduces overall costs and simplifies electrical planning.  
Technical data  
Rated voltage UN  
Current ratings IN  
Frequency  
AC 230 V 10ꢀ  
4 A, 6 A, 10 A, 16 A  
50 Hz  
Typical applications  
Rated insulation voltage AC 250 V  
Rated voltage and  
current rating range of  
the auxiliary contact  
DC 110 V / 0.3 A – 33 W  
Electronic overcurrent protection by means of electronic AC circuit  
breakers is ideally suited to the selective protection of uninterruptible  
power supplies (UPS) in industrial plants. EBU ensures the power  
safety provided by AC UPS systems.  
DC 30 V / 1.1 A – 33 W  
AC 120 V / 0.5 A – 60 VA  
AC 240 V / 0.25 A – 60 VA  
Min. load of aux. contact 3 mA at 24 V  
(valid for standard  
industrial surroundings,  
no aggressive gases)  
Benefits  
Reference ambient  
temperature  
-35 °C...+60 °C  
S-type  
l Enhanced system availability through effective protection  
l Reduction of overall costs by a 1/3 more efficient rating  
l Easy planning with a variable overcurrent protection  
Method of operation  
Mode of trip / degree  
of trip-free behaviour  
mechatronic / trip free  
(positively trip-free)  
4
Order numbering code  
Max.* cable length (outgoing wire) from generator to EBU  
B6  
B10  
B16  
C4  
C6  
C10  
C16  
Type No.  
EBU Electronic circuit breaker for AC UPS applications  
31 m/  
mm2  
19 m/  
mm2  
12 m/  
mm2  
24 m/  
mm2  
17 m/  
mm2  
10 m/  
mm2  
6 m/  
mm2  
Mounting method  
T
rail mounting  
Typical electrical operational values  
Design  
A adjustability IN UPS + IN load  
Number of poles  
Voltage drop in V at 1 x IN  
IN (A)  
V
4
6
10  
16  
1
2
1-pole, 1-pole protected electronically  
2-pole, 1-pole protected electronically  
Version  
0,77  
0,53  
0,35  
0,3  
Insulation co-ordination Rated impulse voltage 4 kV;  
0
with physical isolation by means of MCB 4230-T  
(except signalling)  
overvoltage category III; pollution  
degree 2; reinforced insulation in the  
actuating area  
Signal input  
0
without signal input  
Signal output  
3
auxiliary change-over contact  
Operating voltage  
Insulation co-ordination Rated impulse voltage: 2.5 kV  
of the signalling  
AC 230 V  
voltage rating AC 230 V  
Characteristic curve  
Note: The Si contacts are not suitable for connection to SELV  
control voltage.  
B
thermal 1.05 - 1.30 IN;  
magnetic 3.2 - 4.8 IN  
thermal 1.05 - 1.30 IN;  
magnetic 6.4 – 9.6 IN  
Current rating range  
4 A (only Characteristic curve C)  
6 A  
Insulation resistance  
Degree of protection  
Endurance  
> 100 MOhm (DC 500 V)  
II  
C
mechanical (contacts)  
electronic  
potentiometer  
20,000 cycles  
> 15 years within specification  
min. 1000 steps  
10 A  
16 A  
EBU10 -T A 1 - 0  
0
3 - AC 230 V - C - 10 A  
ordering example  
Preferred types Characteristic curve C  
1638  
www.e-t-a.de  
1

与EBU-TA2-003-AC230V-B-16A相关器件

型号 品牌 获取价格 描述 数据表
EBU-TA2-003-AC230V-B-4A ETAL

获取价格

Electronic circuit breaker EBU
EBU-TA2-003-AC230V-B-6A ETAL

获取价格

Electronic circuit breaker EBU
EBU-TA2-003-AC230V-C-10A ETAL

获取价格

Electronic circuit breaker EBU
EBU-TA2-003-AC230V-C-16A ETAL

获取价格

Electronic circuit breaker EBU
EBU-TA2-003-AC230V-C-4A ETAL

获取价格

Electronic circuit breaker EBU
EBU-TA2-003-AC230V-C-6A ETAL

获取价格

Electronic circuit breaker EBU
EBV02A ADAM-TECH

获取价格

EURO BLOCKS TS & EB SERIES
EBV02B ADAM-TECH

获取价格

EURO BLOCKS TS & EB SERIES
EBV02H ADAM-TECH

获取价格

EURO BLOCKS TS & EB SERIES
EBV02J ADAM-TECH

获取价格

EURO BLOCKS TS & EB SERIES