DS2482-800: 8-Channel 1-Wire Master  
Channel Selection Register  
The content of the Channel Selection Register specifies which of the channels is selected and will be the target of  
subsequent 1-Wire communication commands. The DS2482-800 supports eight 1-Wire communication channels  
IO0 to IO7. Only one of these channels can be active/selected at any time. Once selected, a 1-Wire channel  
remains selected until a different channel is selected through the Channel Select command or by initiating a  
device reset. After a device reset (power-up cycle or initiated by the Device Reset command) the IO0 channel is  
selected.  
Configuration Register  
The DS2482 supports allows three 1-Wire features that are enabled or selected through the Configuration Register.  
These features are:  
.
.
.
Active Pullup (APU)  
Strong Pullup (SPU)  
1-Wire Speed (1WS)  
These features can be selected in any combination. They apply equally to all 1-Wire channels. While APU, PPM  
and 1WS maintain their state, SPU returns to its inactive state as soon as the strong pullup has ended.  
Configuration Register Bit Assignment  
bit 7  
bit 6  
SPU  
bit 5  
1
bit 4  
APU  
bit 3  
bit 2  
SPU  
bit 1  
0
bit 0  
APU  
1WS  
1WS  
After a device reset (power-up cycle or initiated by the Device Reset command) the Configuration Register reads  
00h. When writing to the Configuration Register, the new data is accepted only if the upper nibble (bits 7 to 4) is the  
one's complement of the lower nibble (bits 3 to 0). When read, the upper nibble is always 0h.  
Active Pullup (APU)  
The APU bit controls whether an active pullup (controlled slew-rate transistor) or a passive pullup (RWPU resistor)  
will be used to drive a 1-Wire line from low to high. When APU = 0, active pullup is disabled (resistor mode). Active  
Pullup should always be selected unless there is only a single slave on the 1-Wire line. The active pullup does  
not apply to the rising edge of a presence pulse or a recovery after a short on the 1-Wire line.  
The circuit that controls rising edges (Figure 2) operates as follows: At t1 the pulldown (from DS2482 or 1-Wire  
slave) ends. From this point on the 1-Wire bus is pulled high through RWPU internal to the DS2482. VCC and the  
capacitive load of the 1-Wire line determine the slope. In case that active pullup is disabled (APU = 0), the resistive  
pullup continues, as represented by the solid line. With active pullup enabled (APU = 1), when at t2 the voltage has  
reached a level between VIL1max and VIH1min, the DS2482 actively pulls the 1-Wire line high applying a controlled  
slew rate, as represented by the dashed line. The active pullup continues until tAPUOT is expired at t3. From that time  
on the resistive pullup will continue.  
Figure 2. Rising Edge Pullup  
VCC  
APU = 1  
APU = 0  
VIH1MIN  
VIL1MAX  
0V  
tAPUOT  
1-Wire bus is  
discharged  
t1  
t2  
t3  
6 of 23  

与DS2482-800_12相关器件

型号 品牌 获取价格 描述 数据表
DS2482-800_V01 MAXIM

获取价格

8-Channel 1-Wire Master
DS2482S-100 DALLAS

获取价格

Single-Channel 1-Wire Master
DS2482S-100/R DALLAS

获取价格

Single-Channel 1-Wire Master
DS2482S-100/T DALLAS

获取价格

Single-Channel 1-Wire Master
DS2482S-100/T&R MAXIM

获取价格

Buffer/Inverter Based Peripheral Driver, PDSO8, 0.150 INCH, SOP-8
DS2482S-100/T&R DALLAS

获取价格

Single-Channel 1-Wire Master
DS2482S-100+ MAXIM

获取价格

Single-Channel 1-Wire Master
DS2482S-100+TR MAXIM

获取价格

Single-Channel 1-Wire Master
DS2482S-101+ MAXIM

获取价格

Single-Channel 1-Wire Master with Sleep Mode
DS2482S-101+T&R MAXIM

获取价格

Buffer/Inverter Based Peripheral Driver, PDSO8, 0.150 INCH, ROHS COMPLIANT, SOP-8