DP6-1P
industrial relays
• Relays DP6-1P - with changeover relay, rated load 6 A / 250 V (AC1)
• 35 mm DIN rail mount, EN 50022,
wires connection with screw terminals - 0.2...4 mm2
• Adapted for the co-operation with interconnection strip type DG20
• Equipped in LED green
R
• Recognitions, certificates, directives:
VDE
Contacts
Contact number & arrangement
1C/O
Contact material
Max. switching voltage
Min. switching voltage
Rated load
AgSnO , AgSnO /Au 3 um
250 V / 220 V
2
2
AC/DC
AC/DC
AC1
AgSnO : 12 V
AgSnO /Au 3 um: 100 mV
2
2
AgSnO : 6 A / 250 V AC
AgSnO /Au 3 um: 50 mA / 30 V AC
2
2
DC1
AgSnO : 6 A / 24 V DC
AgSnO /Au 3 um: 50 mA / 36 V DC
2
2
Min. switching current
Max. inrush current
Rated current
AgSnO : 8 mA / 24 V
AgSnO /Au 3 um: 2 mA / 24 V
AgSnO /Au 3 um: 100 mA ❶
2
2
2
AgSnO : 15 A
2
6 A
Max. breaking capacity
Resistance - initially
Max. operating frequency
• at rated load
AC1
AC1
AgSnO : 1 500 VA
AgSnO /Au 3 um: 1.5 VA
2
2
AgSnO : ≤ 50 mΩ 100 mA, 24 V AgSnO /Au 3 um: ≤ 25 mΩ 100 mA, 5 V
2
2
360 cycles/hour
• no load
72 000 cycles/hour
Input control circuit
Rated voltage
50/60 Hz AC
DC
95...230 V
12-24-36 V
AC/DC
24-42-115-230 V AC: 50/60 Hz
Must release voltage
AC: ≥ 0.2 U
DC: ≥ 0.1 U
see Table 1
AC and DC: ≤ 0.7 U
AC: ≥ 0.5 U
❷
❷
n
n
n
Operating range of supply voltage
Must operate voltage
n
AC: 0.6...0.85 U
❷
DC: ≤ 0.8 U
n
n
Input polarization current
Rated power consumption
AC: 8 mA < I < 10 mA 230 V AC ❷
0.35...2.2 VA
0.3...1.6 W
p
AC
DC
Insulation
Insulation category
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
• coil - contact
C250
400 V AC
4 000 V AC
III
3
IEC 61810-5 (PN-IEC 664-1)
4 000 V AC
1 000 V AC
• contact - contact
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive AC1
• cos φ = 0,4
AC: 7 ms
AC: 15 ms
DC: 6 ms
DC: 10 ms
5
> 0.6 x 10
6 A, 250 V AC
2 A, 250 V AC
6 A, 30 V DC
5
> 2 x 10
5
• resistive DC1
10
≤ 0.3 Nm
Rated torque for screw terminals
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
7
> 2 x 10
80 x 6.2 x 93.8 mm
40 g
Ambient temperature
• storage
• operating
o
o
o
-40...+70
-40...+55
C
C
o
-40...+60 C 12, 24 V DC
o
-40...+40 C 230 V AC ❷ -40...+50 C 230 V DC ❷
Protection category
IP 20
RTI IEC 61810-7
Environmental protection
Standard contact materials and coil rated voltages are marked with bold type.
❶ Max. inrush current 50 mA at voltage 30 V AC or 36 V DC
❷ Refer version PI6-1P-230VAC/DC-10 - relay with anti-disturbance circuit
Page 1 of 2
www.aecsensors.com
Sales Department Tel: (888) 847-6552