DP6-1T
industrial relays
• Relays DP6-1T - with triac output 1.2 A / 400 V AC
• 35 mm DIN rail mount, EN 50022,
wires connection with screw terminals - 0.2...4 mm2
• Adapted for the co-operation with interconnection strip type DG20
• Equipped in LED green
• Recognitions, certificates, directives:
Triac - output
Max. switching voltage
Min. switching voltage
Rated load
Min. switching current
Max. non-repeat surge current
Rated current
AC
AC
AC1
400 V
20 V
1.2 A / 400 V AC
10 mA
30 A
t=20 ms
1.2 A
I2t for fusing
dI/dt
dV/dt
5.1 A2s
50 A/us
40 V/us
70 oC/W
t=1-10 ms
Rth junction to ambient
Input control circuit
Rated voltage
DC
5...32 V
AC/DC
24-230 V AC: 50/60 Hz
AC: ≥ 0.2 Un DC: ≥ 0.1 Un
0.3 W
Turn-off voltage
Rated power consumption
5...32 V DC at 24 V
0.3 VA / 0,3 W 24 V AC/DC
1.6 VA / 1,6 W 230 V AC/DC
Insulation
Insulation category
C250
Insulation rated voltage
Rated insulation voltage I/O
Insulation pollution degree
600 V AC
4 000 V AC
2
General data
Operating time
Release time
10 ms
10 ms
max. (zero turn-on)
max.
Dimensions (L x W x H)
Weight
80 x 6.2 x 93.8 mm
40 g
Ambient temperature
• storage
• operating
Protection category
Environmental protection
-40...+70 oC
-40...+55 oC
IP 20
RTI IEC 61810-7
Page 1 of 2
www.aecsensors.com
Sales Department Tel: (888) 847-6552