Applicable standard
Operating
Storage
temperature range
Storage
-35 C to +85C (Note1)
-10 C to +60C (Note3)
temperature range
Operating
Rating
40% to 80% (Note2)
40% to 70% (Note3)
humidity range
Applicable connector
Voltage
humidity range
Current
AWG 18 : 8.0 A
AWG 20 : 6.0 A
AWG 22 : 5.0 A
DF5A-*S-5C
500
V
AC/DC
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance
30 m MAX.
100mA (DC or 1000Hz).
-
X
Millivolt level method
Insulation resistance
500 V DC.
1000 M MIN.
-
-
X
X
1500 V AC for 1 min.
No flashover or breakdown.
Voltage proof
Mechanical characteristics
30 times insertion and extraction.
①Contact resistance: 30 mΩ MAX.
Mechanical operation
-
-
X
X
②No damage, crack or looseness of parts.
①No electrical discontinuity of 10μs.
②No damage, crack or looseness of parts.
Frequency 10 to 55Hz, single amplitude
0.75 mm, at 2h, for 3 directions.
Vibration
490 m/s2 duration of pulse 11 ms at 3 times for 3 directions.
Shock
-
-
X
X
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
①Contact resistance: 30 mΩ MAX.
②Insulation resistance: 500 M MIN.
③No damage, crack or looseness of parts.
①Contact resistance: 30 mΩ MAX.
②Insulation resistance: 1000 M MIN.
③No damage, crack or looseness of parts.
No deformation on case or excessive
looseness of the terminals.
(Steady state)
(After leaving the room temperature for
1-2h.)
Rapid change of temperature Temperature -55 →5 to 35→ 85 →5 to 35 c
Time 30 → 30 → 5 min
Under 5 cycles.
-
-
X
X
5
→
Resistance to soldering heat
[Recommended temperature profile]
Solder temperature 260±3℃ for immersing
duration 10±1s.
[Recommended manual soldering condition]
Soldering iron temperature:350±5℃
for within 3±1s
No strength on contact.
Solderability
Remarks
Soldered at solder temperature : 235c
For in immersing duration : 5s.
New uniform coating of solder shall
cover minimum of 95 of the surface
being immersed.
-
X
Note 1:Include the temperature rising by current.
Note 2:No condensing
Note 3:Apply to the condition of long term storage for unused products before pcb on board,
after pcb on board, operating temperature and humidity range is applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
0
△
Approved
Checked
Designed
Drawn
KI.AKIYAMA
TS.FUKUSHIMA
MI.SAKIMURA
MI.SAKIMURA
15.08.19
15.08.19
15.08.19
15.08.19
Unless otherwise specifid , refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing no.
ELC-160242-35-00
DF5A-*P-5DSA(35)
Part no.
Specification sheet
Hirose electric co., ltd.
0
△
1/1
Code no.
CL676-