Document 133
50/60Hz Current Sensor – CS60-010
This Coilcraft current sensor is intended for measuring
current from 1 to 10 Arms. The sensor functions as the
encapsulated secondary of a current transformer, while
the conductor carrying the current to be measured serves
as the “one turn primary.” Sensitivity may be enhanced by
increasing primary turns.
Minimum wall thickness of the hole is 0.5 mm to meet
IEC 380 and other requirements when used with an in-
sulated conductor.
Applications include sensing branch circuit overload and
detecting load drop or shutdown.
Coilcraft Designer’s Kit P403 contains two samples
of this sensor and 15 samples of nine different high
frequency current sensors.To order, contact Coilcraft or
visit http://order.coilcraft.com.
Part
Sensed
current Irms
Vout
tolerance
number1
Typical Response
CS60-010_
1–10 Arms
10ꢀ
100
90
(For sensed current above 10 Arms, see CS60 data sheet)
1. When ordering, please specify termination code:
CS60-010L
Termination: L = RoHS compliant tin-silver over copper.
Special order: T = RoHS tin-silver-copper (95.5/4/0.5)
or S = non-RoHS tin-lead (63/37).
80
70
60
50
40
30
20
10
2. Ambient temperature range −40°C to +85°C.
3. Electrical specifications at 25°C.
0.75
19,05
max
0.550
13,97
max
Date code
0.125
min
3,175
0.80
max
20,30
1
2
3
4
5
6
7
8
9
10
0.033 0.002
0,84 0,05
Current (A rms)
0.45
11,43
max
0.34
8,64
max
3
Typical Application
3
1
0.125
0.50 0.015
12,7 0,38
I
rms
max
3,175
inches
mm
Dimensions are in
−
3
+
1
Weight: 5.8 g
50⏲
V
rms
out
Document 133 Revised 02/01/05
US +1-847-639-6400 sales@coilcraft.com
UK +44-1236-730595 sales@coilcraft-europe.com
Taiwan +886-2-2264 3646 sales@coilcraft.com.tw
China +86-21-6218 8074 sales@coilcraft.com.cn
Singapore + 65-6484 8412 sales@coilcraft.com.sg
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.