CP-602E-I Series
2-port CAN interface PCI Express boards with 2 kV isolation
Features and Benefits
• Supports CAN 2.0A and CAN 2.0B
• Two independent CAN communication ports
• CAN transfer rate up to 1 Mbps
• 2 kV electrical isolation
• LED for transmit/receive status on each port
• Optional 120-ohm terminal resistor for CAN bus network
• DLL library and examples included
• Windows driver provided
Certifications
Introduction
Moxa’sCP-602E-I CAN (Controller Area Network) interface board supports the PCI Express interface. As a standalone CAN controller, the CP-602E-
I is a cost-effective solution that provides two active CAN controllers with a DB9 connector on the same board. The CP-602E-I CAN interface board
uses the NXP SJA1000 and transceiver PCA82C251, which provide bus arbitration and error detection. The -40 to 85°C wide operating temperature
(CP-602E-I-T only) and 2 kV isolation make the boards suitable for use in harsh industrial environments.
Specifications
CAN Interface
Baudrate
10/20/50/125/250/500/800/1000 kbps, user-defined
Connector
No. of Ports
DB9 male
2
Environmental Limits
Operating Temperature
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature (package included)
Ambient Relative Humidity
-40 to 85°C (-40 to 185°F)
5 to 95% (non-condensing)
Standards and Certifications
EMC
EN 55032/24
EMI
CISPR 32, FCC Part 15B Class B
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
1