CITR2
CIRCUIT BREAKER WITH ON/OFF CAPABILITY
This unique circuit breaker consists of a thermal circuit
breaker and a rocker switch style housing. When an
overload condition occurs, the contacts will break apart.
By returning the actuator to the OFF position, then back
to ON, the circuit breaker mechanism with reset.
SPECIFICATIONS
Electrical Ratings
Electrical Life
8A, 10A, 12A, 15A @ 125VAC
10,000 cycles typical
- E198027
Contact Resistance
Dielectric Strength
Insulation Resistance
Interrupt Capacity
Operating Temperature
Storage Temperature
< 30 mΩ max initial @ 2-4VDC, 100mA
3000Vrms min (Terminal – Terminal)
> 1,000MΩ min
1000A @ 125VAC
-40°C to 85°C
-40°C to 85°C
MATERIALS ←RoHS COMPLIANT
Actuator
Housing
Rivits
PC (Poly Carbonate)
Nylon
Aluminum
AgSnO2
Contacts
Terminals
Brass
TRIP TIMES / CURRENT LEVELS
% of Rated Current
Trip Time
No Trip
100
150
200
300
400
500
600
< 1 Hour
3.5 – 60 Sec.
0.7 – 10 Sec.
0.35 – 5 Sec.
0.2 – 2.8 Sec.
0.1 – 1.8 Sec.
ORDERING INFORMATION
1. Series:
CITR2
15
Q2
L
S
CITR2
2.Contact Ratings:
08 = 8A
10 = 10A
12 = 12A
15 = 15A
3. Termination Options:
Q1 = Short Quick Connects
Q2 = Long Quick Connects
RP = Right Angle PC Pins
4. Lamp Options:
N = No Lamp, Opaque Red Actuator
L = 125VAC Neon, Translucent Red Actuator
K = No Lamp, Translucent Red Actuator
G = 125VAC Neon, Translucent Green Actuator
H = No Lamp, Translucent Green Actuator
5. Printing Options:
None = No Printing
S = Reset / OFF
Website: www.citswitch.com