BR8
Crystal Can
DPDT
Dry Circuit to 2 Amps
SPECIFICATIONS
GENERAL
Contact Resistance:
Before Life...............0.050 Ohms max. @ 2 Amps and
Contact Arrangement .......................... 2PDT (2 Form C)
Weight......................................................... 1.0 oz approx.
Designed to meet the requirements of MIL-PRF-39016.
6 VDC
After Life..................0.100 Ohms max. @ 2 Amps and
6 VDC
ENVIRONMENTAL
PERFORMANCE
Contact Rating (Note 1)
Temperature Range............................... -65oC to +125oC
Vibration (Note 2)............................... 0.4" DA 10 - 38 Hz,
20 G's 38 - 2,000 Hz
Resistive ...............2 Amps @ 28 VDC or 115V 400 Hz
(Case Ungrounded)
Shock (Operating) (Note 2) ........................ 50 G's 11 ms
Inductive ........................................... 1 Amp @ 28 VDC
Low Level ............................10-50 µA @ 10-50 mv DC
or peak AC, (Note 4)
ELECTRICAL CHARACTERISTICS
Duty Cycle........................................................Continuous
Insulation Resistance
Life ...................................100,000 operations minimum
@ 2 Amps load, 125oC
10,000 megohms @ 500V 25oC
Pull In Power:
1,000 megohms @ 500V 125oC
BR8.......................................................250 mw approx.
BR8H....................................................150 mw approx.
Dielectric Strength:
Sea Level:
Contact to Case................................... 1,000 VRMS
Contact to Coil ..................................... 1,000 VRMS
Coil to Case ......................................... 1,000 VRMS
Across Open Contacts ........................... 750 VRMS
70,000 Feet
Operate/Release Time:
BR8.................................................................5 ms max
BR8H..............................................................6 ms max
Excluding bounce time at nominal coil voltage
Contact Bounce Time.....................2 ms max @ 2 Amps
6 VDC contact load
All points.................................................. 350 VRMS
Notes:
1.
For case grounded loads and other ratings, consult
the factory.
3.
4.
For other ratings consult the factory.
Relay contacts which have switched high level
currents are no longer suitable for switching low
level loads.
2.
For applications requiring other shock and vibration
levels, consult the factory.
14930 E. Alondra Blvd., La Mirada, CA 90638-5752 (714) 994-6500 FAX (714) 994-3013
W:2000, Rev. 2