BCM® in a VIA Package
Bus Converter
BCM3814x60E10A5yzz
Isolated Fixed-Ratio DC-DC Converter
Features & Benefits
Product Ratings
• Up to 150A continuous low voltage side current
• Fixed transformation ratio(K) of 1/6
• Up to 769W/in3 power density
• 97.2% peak efficiency
VHI = 54V (36 – 60V)
ILO = up to 150A
K = 1/6
VLO = 9V (6 – 10V)
(no load)
Product Description
• Integrated ceramic capacitance filtering
• Parallel operation for multi-kW arrays
• OV, OC, UV, short circuit and thermal protection
• 3814 package
The BCM in a VIA package is a high efficiency Bus Converter,
operating from a 36 to 60VDC high voltage bus to deliver an
isolated 6 to 10VDC unregulated, low voltage.
This unique ultra-low profile module incorporates DC-DC
conversion, integrated filtering and PMBus™ commands and
controls in a chassis or PCB mount form factor.
• High MTBF
• Thermally enhanced VIA™ package
• PMBusTM management interface
The BCM offers low noise, fast transient response and industry
leading efficiency and power density. A low voltage side referenced
PMBus™ compatible telemetry and control interface provides
access to the BCM’s internal controller configuration, fault
monitoring, and other telemetry functions.
Typical Applications
Leveraging the thermal and density benefits of Vicor’s VIA
packaging technology, the BCM module offers flexible thermal
management options with very low top and bottom side thermal
impedances.
• DC Power Distribution
• Information and Communication
Technology (ICT) Equipment
When combined with downstream Vicor DC-DC conversion
components and regulators, the BCM allows the Power Design
Engineer to employ a simple, low-profile design which will
differentiate the end system without compromising on cost or
performance metrics.
• High End Computing Systems
• Automated Test Equipment
• Industrial Systems
• High Density Energy Systems
• Transportation
Size:
3.76 x 1.40 x 0.37 in
95.59 x 35.54 x 9.40 mm
Part Ordering Information
High
Side
Voltage
Range
Ratio
Max
High
Side
Max
Low
Side
Max
Low
Side
Product
Function
Package
Length
Package
Width
Package
Type
Product Grade
(Case Temperature)
Option Field
Voltage
Voltage Current
BCM
38
14
x
60
E
10 A5
y
zz
BCM =
Bus Converter
Module
02 = Chassis/PMBus
06 = Short Pin/PMBus
10 = Long Pin/PMBus
Length in
Width in
B = Board VIA
C = -20 to 100°C[1]
T = -40 to 100°C[1]
Internal Reference
Inches x 10 Inches x 10 V = Chassis VIA
[1] High Temperature Current Derating may apply; See Figure 1, specified thermal operating area.
BCM® in a VIA Package
Page 1 of 39
Rev 1.4
09/2016
vicorpower.com
800 927.9474