BC2502A/BC2502B
Absolute Maximum Ratings
Storage Temperature ............................-60℃ to150℃
Operating Temperature ........................ -40°C to 85°C
ESD HBM......................................................... ±2kV
Supply Voltage.................................VSS-0.3V to 5.5V
Input Digital Voltage...............VSS-0.3V to VDD+0.3V
Input Analog Voltage ......................VSS-0.3V to 2.1V
*Devices being ESD sensitive. HBM (Human Body Mode) is based on MIL-STD-883.
Note: These are stress ratings only. Stresses exceeding the range specified under “Absolute Maximum Ratings”
may cause substantial damage to the device. Functional operation of this device at other conditions beyond
those listed in the specification is not implied and prolonged exposure to extreme conditions may affect
device reliability.
D.C. Characteristics
Ta=25°C, VDD=5.0V, fXTAL=16MHz, FSK demodulation with matching circuit, unless otherwise specified
Symbol
TOP
VDD
Current Consumption
ISLP Current Consumption, Deep Sleep Mode
Parameter
Operating Temperature
Operating Voltage
Conditions
Min.
-40
Typ.
—
Max.
85
Unit
°C
—
—
2.4
5.0
5.5
V
—
—
—
—
—
—
—
0.5
4.7
4.5
5.8
5.8
100
—
—
—
—
—
—
μA
mA
kΩ
@ 315MHz
@ 433MHz
@ 868MHz
@ 915MHz
IRX
Current Consumption, RX Mode
RPH
Pull-high Resistance for I/O Ports
—
A.C. Characteristics
Ta=25°C, VDD=5.0V, fXTAL=16MHz, FSK demodulation with matching circuit, unless otherwise specified
Symbol
Parameter
Conditions
Min.
Typ.
Max.
Unit
Receiver Characteristics
BC2502A/BC2502B
BC2502A/BC2502B
BC2502B only
—
—
—
—
1
315
433.92
868.35
915
—
—
—
—
—
50
25
—
—
—
—
—
—
—
—
-57
-47
—
—
fRF
RF Frequency Range
MHz
BC2502B only
SR
fDEV
Symbol Rate
—
Ksps
Frequency Deviation
—
4
—
kHz
SR=1Ksps, BER=0.1%
SR=10Ksps, BER=0.1%
SR=1Ksps, BER=0.1%
SR=10Ksps, BER=0.1%
SR=5Ksps, BER=0.1%
SR=10Ksps, BER=0.1%
SR=5Ksps, BER=0.1%
SR=10Ksps, BER=0.1%
25MHz~1GHz
—
—
—
—
—
—
—
—
—
—
—
—
-105
-108
-106
-108
-105
-105
-104
-104
—
RX Sensitivity – 315MHz
(Instrument: Keysight E4438C)
RX Sensitivity – 433.92MHz
(Instrument: Keysight E4438C)
(1)
PSENS
dBm
RX Sensitivity – 868.35MHz
(Instrument: Keysight E4438C)
RX Sensitivity – 915MHz
(Instrument: Keysight E4438C)
SERX
Receiver Spurious Emission
dBm
dBc
Above 1GHz
—
±2MHz offset
40
Blocking Immunity
±10MHz offset
64
Rev. 1.20
3
December 05, 2022