AZ695
SENSITIVE
SUBMINIATURE RELAY
FEATURES
• Extremely small footprint utilizing only 0.18 square inch
of PCB area
• Thin vertical profile only 0.256" wide
• 1 Form A contact with up to 5 Amp switching capability
• High sensitivity, 100 mW pickup
• Dielectric strength 3000 Vrms contact to coil
• Coils to 24 VDC
• Epoxy sealed for automatic wave soldering
and cleaning
• UL file E44211; CSA file 74461
CONTACTS
GENERAL DATA
Arrangement
Ratings
SPST (1 Form A)
Resistive load:
Life Expectancy
Mechanical
Electrical
Minimum operations
20 million operations
1 X 105 at 5 A, 30 VDC or 250 VAC Res.
Max. switched power: 150 W or 1250 VA
Max. switched current: 5 A
Operate Time (typical) 6 ms at nominal coil voltage
Max. switched voltage: 150* VDC or 250 VAC
Inductive load (p.f. = 0.40, L/R = 7 ms)
2 A at 250 VAC, 30 VDC
Release Time (typical) 3 ms at nominal coil voltage
(with no coil suppression)
Dielectric Strength
(at sea level for 1 min.) 3000 Vrms contact to coil
750 Vrms between open contacts
UL/CSA Ratings 5 A at 30 VDC resistive
5 A at 250 VAC general use
1/10 HP 120 VAC
Insulation
Resistance
100 megohms min. at 20°C, 500 VDC,
50% RH
Note: If switching voltage is greater than 30 VDC, special
precautions must be taken. Please contact the factory.
Dropout
Greater than 10% of nominal coil voltage
Material
Options:
Silver cadmium oxide
Silver cadmium oxide with gold plating
Ambient Temperature At nominal coil voltage
Operating
Storage
-40°C (-40°F) to 70°C (158°F)
-40°C (-40°F) to 105°C (221°F)
Resistance
< 30 milliohms initially
(6 V, 1 A, voltage drop method)
Vibration
0.062" DA at 10–55 Hz
10 g
COIL
Shock
Power
Enclosure
P.B.T. polyester
Tinned copper alloy, P.C.
270°C (518°F)
5 seconds
At Pickup Voltage
(typical)
100 mW
Terminals
Max. Solder Temp.
Max. Solder Time
Max. Solvent Temp.
Max. Continuous
Dissipation
550 mW at 20°C (68°F) ambient
420 mW at 40°C (104°F) ambient
Temperature Rise
Temperature
25°C (45°F) at nominal coil voltage
Max. 105°C (221°F)
80°C (176°F)
Max. Immersion Time 30 seconds
Weight 3 grams
NOTES
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Minimum permissible contact load:
SCO contact: 100 mA at 5 VDC
SCO contact with gold plating: 10 mA at 5 VDC
4. Specifications subject to change without notice.
7/12/01W