AC Current transducer APR-B10
IPN = 10 .. 400 A
Split core transducer for the electronic measurement distorted AC
waveforms current, with galvanic isolation between the primary (High
power)andthesecondarycircuits(Electroniccircuit).Switchselectable
rangesandTrueRMS0-5Vand0-10Vswitchselectablevoltageoutput.
Electrical data
Primary Nominal Current
IPN (A.t.RMS)
Analogue Output Signal
VOUT (V)
Type
Features
· VFD and SCR waveforms current
measurement
10,25,50
0-5V or 0-10V
0-5V or 0-10V
0-5V or 0-10V
0-5V or 0-10V
APR 50 B10
APR 100 B10
APR 200 B10
APR 400 B10
50,75,100
100,150,200
200,300,400
· True RMS output
· Split core type
RL
VC
IC
Load resistance
Supply voltage
Current Consumption
Limitation of voltage output (0-10V)
Limitation of voltage output (0-5V)
Overloaded input current
³ 10
+24 ±5% V DC
< 30
14
7
kW
· 5V & 10V switch selectable voltage
output
mA
V
V
· DIN mounting & Panel mounting
· Eliminates insertion loss
· Switch selectable ranges
no limitation
Accuracy-Dynamic performance data
X
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
< ±1
< ±0.5 % of IPN
< ±0.5 % of IPN
±1
±0.1
< 400
% of IPN
Advantages
e
VOLE
VOT
TCe
tr
Electrical offset voltage, TA = 25°C
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (±1%)
· Large aperture for cable up to
Ø18mm
mV/K
%/K
m s
G
· High isolation between primary and
secondary circuits
f
30 .. 6000 Hz
· Easy to mount
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
-20 .. +60
-20 .. +85
90
°C
°C
g
Applications
Protection type
IP20
5.5
5.5
600
V0
· VFD Controlled Loads:
dCp
dCl
CTI
Creepage distance
Clearance distance
Comparative tracking index (Group I)
UL94 classification
m m
m m
V
VFD output indicates how the motor
and attached load are operating.
· SCR Controlled Loads:
Acurate measurement of phase
angle fired or burst fired (time
proportioned) SCRs. Current
measurement gives faster
response than temperature
measurement.
Insulation category
Vb
Rated Voltage
with IEC 61010-1 standards and following conditions :
- Single insulation
300
V
- Over voltage category CAT III
- Pollution degree PD2
- None uniform field
R.m.s. voltage for AC insulation test, 50Hz, 1mn
R.m.s. voltage for partial discharge extinction @ 10pC 1.5
Peak impulse withstand voltage 1.2/50ms 6.1
If insulated cable is used for the primary circuit, the voltage category
could be improved with the following table :
· Switching Power Supplies and
Electronic Ballasts:
Vd
Ve
Vw
5
kV
kV
kV
True RMS sensing is the most
accurate way to measure power
supply or ballast input power.
Cable insulation (primary)
HAR 05
Category
600V CAT III
1000V CAT III
HAR 07
041029/3
Notes : Installation and maintenance should be done with power supply disconnected.
The operator must have accrediation to install this material.
The users must take care of all protection gurantee against electrical shock.
LEM Components
www.lem.com