5秒后页面跳转
APR200B420L PDF预览

APR200B420L

更新时间: 2024-10-28 03:19:15
品牌 Logo 应用领域
莱姆 - LEM /
页数 文件大小 规格书
3页 874K
描述
AC Current transducer

APR200B420L 数据手册

 浏览型号APR200B420L的Datasheet PDF文件第2页浏览型号APR200B420L的Datasheet PDF文件第3页 
AC Current transducer APR-B420L  
IPN = 10 .. 400 A  
Split core transducer for the electronic measurement distorted AC  
waveforms current, with galvanic isolation between the primary circuit  
(power) and the secondary circuit (measurement). Switch selectable  
ranges and True RMS 4-20mA current output.  
Electrical data  
Features  
PrimaryNominalCurrent  
IPN (A.t.rms)  
Output Current  
IOUT (mA)  
Type  
RoHS since  
date code  
· VFD and SCR waveforms current  
measurement  
· True RMS output  
10,25,50  
4-20  
4-20  
4-20  
4-20  
APR 50 B420L  
APR 100 B420L  
APR 200 B420L  
APR 400 B420L  
planned  
planned  
46317  
50,75,100  
100,150,200  
200,300,400  
· Split core type  
46291  
· Loop powered 4-20mA current output  
· DIN mounting & Panel mounting  
· Eliminates insertion loss  
· Switch selectable ranges  
· Isolated plastic case recognized  
according to UL94-V0.  
RL  
Load resistance  
(See the graph "Load Resistance vs. Supply Voltage") < 350  
W
VC  
ISL  
ÎP  
Supply voltage (loop powered)  
Output current limitation  
Overload capability  
+ 12 .. 24 V DC  
< 25 mA  
no limitation  
Advantages  
Accuracy-Dynamic performance data  
· Large aperture for cable up to  
Ø18mm  
· High isolation between primary and  
secondary circuits  
X
Accuracy @ IPN, TA = 25°C (excluding offset)  
Linearity error (0 .. ± IPN)  
< ± 1 % of IPN  
< ± 0.5 % of IPN  
e
L
IOE  
Electrical offset current @ TA = 25°C  
4
mA  
mA/K  
%/K  
m s  
TCIOE  
TCIOUT  
tr  
Temperature coefficient of IOE  
± 1  
· Easy installation  
Temperature coefficient of IOUT (% of reading)  
Response time to 90% of IPN step  
Frequency bandwidth (± 1 %)  
± 0.1  
< 400  
Applications  
BW  
30 .. 6000 Hz  
· VFD Controlled Loads:  
VFD output indicates how the motor  
and attached load are operating.  
· SCR Controlled Loads:  
General data  
TA  
Ambient operating temperature  
Ambient storage temperature  
Mass  
- 20 .. + 60 °C  
- 20 .. + 85 °C  
TS  
Acurate measurement of phase  
angle fired or burst fired (time  
proportioned)  
m
90  
g
IPxx  
Protection degree  
IP20  
SCRs. Current measurement gives  
faster response than temperature  
measurement.  
· Switching Power Supplies and  
Electronic Ballasts:  
True RMS sensing is the most  
accurate way to measure power  
supply or ballast input power.  
Application domain  
· Energy and Automation  
Page 1/3  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
070125/4  
www.lem.com  

与APR200B420L相关器件

型号 品牌 获取价格 描述 数据表
APR200-B420L LEM

获取价格

AC Current transducer APR-B420L
APR27-27-12CB CTS

获取价格

Forged Heat Sinks
APR27-27-12CB/S CTS

获取价格

Forged Heat Sinks
APR27-27-15CB CTS

获取价格

Forged Heat Sinks
APR27-27-15CB/S CTS

获取价格

Forged Heat Sinks
APR27-27-20CB CTS

获取价格

Forged Heat Sinks
APR27-27-20CB/S CTS

获取价格

Forged Heat Sinks
APR27-27-25CB CTS

获取价格

Forged Heat Sinks
APR27-27-25CB/S CTS

获取价格

Forged Heat Sinks
APR29-29-12CB CTS

获取价格

Forged Heat Sinks