Click on Series name for product info on aimtec.com
Series AMEPR60C-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
AC-DC Constant Current or Constant
Voltage LED Driver
Input range 90-305VAC/47-440Hz
High Efficiency up to 89%
Operating temperature -40 to 85°C
Dimmable via resistive / 0-10Vdc / PWM
5 Years Limited Warranty
Over Temperature Protection
Over Current Protection
Waterproof Case rated IP68
Power Factor Correction
Short Circuit Protection
Models
Single output
Output
Voltage
Range
Max
Output
Power
Output
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of
Operation
OCP /
OVP
Efficiency
Current
Model
(%)
③
(A)
③
①
(V)
(W)
1.27
50.7
1.77
36.6
2.55
24.5
5.2
90-305 /
47-440
AMEPR60C-50120AZ
AMEPR60C-36170AZ
AMEPR60C-24250AZ
36-50
24-36
12-24
5-12
0 - 1.20
0 - 1.70
0 - 2.50
0 - 5.0
130-430
130-430
130-430
130-430
Constant Current
Constant Current
Constant Current
Constant Current
60
59.8
60
89
88
87
85
90-305 /
47-440
90-305 /
47-440
90-305 /
47-440
AMEPR60C-12500AZ
60
12.3
①
Exceeding the maximum output power will permanently damage the converter
The dimming feature is not supported when units are used in Constant Voltage mode only.
In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
②
③
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
Note: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMEPR60C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone
to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause
early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
277VAC
Typical
30
Maximum
Units
Inrush current <2ms
A
50
0.5
0.7
0.73
0.33
Leakage current
AC current
mA
A
0.98
0.96
0.93
Power Factor
External fuse
Start up time
Surge voltage
250V/1.5A
250
ms
V
2sec
440
www.aimtec.com
F 052.1e R3.G
Tel: +1 514 620 2722
1 of 13
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only