Series AMEPR60N-Z
up to 1400mA | AC-DC LED driver
FEATURES:
• Universal Input: 90~264 Vac
• High Efficiency: Up to 86%
• Active Power Factor Correction
• Short Circuit / Open Circuit Protection
•
Meet UL, CE Safety Requirement
Long Life, High reliability
Ultra-low ripple without flickering
3-year limited warranty
•
•
•
Models
Single output
Max Output
Power (W)
58.8
Output Voltage
Range (V)
24-42
Output Current
(mA)
1400
Input Voltage
(VAC/Hz)
90-264/47-63
Efficiency
Model
(%)
86
AMEPR60N-42140Z
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Conditions
Typical
Maximum
0.86
40
60
0.75
1.5
Units
Arms
90 VAC, full load
115 VAC, cold start
230 VAC, cold start
Input Current
Inrush current <2ms
Leakage current
Input dissipation
A
mA
W
W
No Load
Output Short
5.0
115 VAC, full load
230 VAC, full load
0.98
0.95
Power Factor
Input Fuse
2A/250V
115 VAC, full load
230 VAC, full load
1.5
1.0
Sec.
Sec.
Start-up Time
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
Maximum
Units
%
%
±5
±3
±5
LL to HL
Full Output Voltage Range
Load regulation
%
Ripple & Noise
Output Current Ripple
200
70
mV p-p
mA
Full load
LL to HL, full load at cold start,
% of rated output current
Current Overshoot
15
%
Hold-up time (min)
0.5
ms
Minimum Load Voltage
See Models Table Above
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
Typical
Rated
3750
Units
VAC
Isolation Resistance
500Vdc
>100
100
MΩ
pF
Isolation Capacitance
General Specifications
Parameters
Switching frequency
Over voltage protection
Short circuit protection
Short circuit restart
Conditions
Typical
Maximum
Units
KHz
V
150
50
Continuous, Hiccup Mode
Auto Recovery
Open circuit protection
Continuous, Hiccup Mode
www.aimtec.com
F 052.1e R1
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only