Series AMEPR8D-AZ
up to 0.7A | AC-DC LED Driver
FEATURES:
• AC-DC Constant Current LED Driver
• Input Range 90-264VAC/47-440Hz
• High Efficiency up to 80%
• Operating Temperature -20 to 85°C
• Total Harmonic Distortion < 20%
•
•
•
•
•
Class 2 Power Supply
Active PFC
SCP, Over Load Protection
Leading or Trailing Edge Triac
IP67 Case
Models
Single output
Efficiency
Output
Voltage
Range
(V)
No Load
Output
Voltage
(V max.)
Max Output
Power
Output
Current
(A)
(%)
Input Voltage
Model
(VAC/Hz)
①
115
230
(W)
VAC
VAC
AMEPR8D-2435AZ
AMEPR8D-1840AZ
AMEPR8D-1270AZ
8.4
7.2
8.4
12-24
9-18
6-12
34
20
15
0.35
0.4
0.7
90-264/47-440
90-264/47-440
90-264/47-440
79
77
75
80
79
78
*Exceeding the maximum output power will permanently damage the converter.
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
AMEPR8D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Typical
Maximum
Units
mA
mA
A
A
mA
85
50
10
Current (full load)
Inrush current <2ms (cold start)
Leakage current
5
230 VAC
0.02
0.98
0.95
115 VAC (full load)
230 VAC (full load)
Recommended slow blow type
Power factor
External fuse
Start-up time
1
100
A
ms
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
±15
±0.5
±5
Maximum
Units
%
%
(LL-HL)
min.-max. load
Load regulation
%
Ripple & Noise*
Hold-up time
1.6
28
V p-p
ms
Minimum load voltage
Maximum Capacitive Load
See the models table
200
µF
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 220µF (E/C) parallel capacitor.
www.aimtec.com
F 052.1e R3.H
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)