Series AMER120C-Z
up to 1700mA | AC-DC LED driver
FEATURES:
• Accurate Constant Current Output ±3%
• High Efficiency: Up to 91%
• Active Power Factor Correction
• UVLO, Short Circuit, Over Voltage
• Adjustable output current: 50-100%
•
IP65/IP67 design for indoor/outdoor
Over Temperature Protection
Dimmable output current: 10-100%
Open circuit protection
•
•
•
•
5 Year Warranty
Models
Single output
Max Output
Power (W)
119
Input Voltage
(VAC/Hz)
90-305/47-63
90-305/47-63
90-305/47-63
90-305/47-63
Output Voltage
Range (V)
35-70
Output Current
Efficiency
Model
(A)
1.7
1.7
1.7
2
(%)
91
90.5
90
AMER120C-70170Z
AMER120C-70170Z-P
AMER120C-70170Z-PD
AMER120C-60200Z
119
119
120
35-70
35-70
42-60
90
Model Nomenclature functional differences:
With Suffix “-PD” With manually adjustable 50-100% & fully dimmable 10-100% (0-10V/10PWM/Resistive) output current
With Suffix “-P”
Only with manually adjustable output current: 50-100%
Without Suffix
Only with fully dimmable 10-100% (0-10V/10PWM/Resistive) output current
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Input Current
Conditions
Typical
Maximum
1.6
Units
Arms
90 VAC, full load
115 VAC, cold start
305 VAC, cold start
45
75
Inrush current <2ms
Leakage current
Input dissipation
A
0.75
3.0
10.0
0.98
0.92
mA
W
W
No Load
Output Short
115 VAC, full load
277 VAC, full load
Power Factor
Input Fuse
3.15A / 300V
115 VAC, full load
277 VAC, full load
1.5
1.0
Sec.
Sec.
Start-up Time
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
Maximum
Units
%
%
%
±3
±1
±1
LL to HL
Full Output Voltage Range
Load regulation
Ripple & Noise
Output Current Ripple
Current Overshoot
Hold-up time (min.)
Minimum Load Voltage
4.5
V p-p
A p-p
%
Full load, 16.7-20ms duration
LL to HL, full load at cold start, % of rated output current
1.5
10
0.5
ms
See Models Table Above
Isolation Specifications
Parameters
Conditions
I/P – O/P
I/P – FG
O/P – FG
I/P – O/P, 500Vdc
Typical
Rated
Units
3750
2000
500
VAC
VAC
VAC
VAC
I/O Isolation Voltage
Isolation Resistance
>100MΩ