Series AMER130-Z
up to 2400mA | AC-DC LED driver
FEATURES:
• Accurate Constant Current Output ±5%
• High Efficiency: Up to 92%
• Active Power Factor Correction
•
•
•
•
IP65/IP67 design for indoor/outdoor
Long Life, High reliability
Over Temperature Protection
5 Year Warranty
• UVLO, Short Circuit, Open Circuit Protection
Models
Single output
Max Output
Output Voltage
Range
Output Current
(mA)
Input Voltage
(VAC/Hz)
Efficiency
(%)
Model
Power
(W)
(V)
AMER130-55240Z
132.0
35-55
2400
90-305/47-63
92.0
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Input Current
Conditions
Typical
Maximum
2.0
Units
Arms
90 VAC, full load
115 VAC, cold start
305 VAC, cold start
40
65
Inrush current <2ms
Leakage current
Input dissipation
A
0.75
2.0
10.0
0.98
0.92
mA
W
W
No Load
Output Short
115 VAC, full load
277 VAC, full load
Power Factor
Input Fuse
5A/300V
115 VAC, full load
277 VAC, full load
1.0
1.0
Sec.
Sec.
Start-up Time
Output Specifications
Parameters
Current accuracy
Line regulation
Load regulation
Ripple & Noise
Output Current Ripple
Current Overshoot
Hold-up time (min.)
Minimum Load Voltage
Conditions
Typical
Maximum
Units
%
%
Io%
mV
Io%
%
±5
±1
±5
LL to HL
Full Output Voltage Range
200
1.0
10
Full load
LL to HL, full load at cold start, % of rated output current
10
15
ms
See Models Table Above
Isolation Specifications
Parameters
Tested I/O Isolation Voltage
Conditions
I/P – O/P
I/P – FG
O/P – FG
I/P – O/P, 500Vdc
Typical
Rated
Units
3750
2000
500
VAC
VAC
VAC
VAC
pF
Isolation Resistance
Isolation Capacitance
>100MΩ
3000
General Specifications
Parameters
Switching frequency
Over voltage protection
Short circuit protection
Conditions
Typical
100
Maximum
Units
KHz
V
220
63
Continuous current mode
www.aimtec.com
F 052.1e R0
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only