5秒后页面跳转
AFL12015DZ/ES PDF预览

AFL12015DZ/ES

更新时间: 2024-10-27 23:28:11
品牌 Logo 应用领域
其他 - ETC 转换器
页数 文件大小 规格书
10页 121K
描述
DC to DC Converter

AFL12015DZ/ES 数据手册

 浏览型号AFL12015DZ/ES的Datasheet PDF文件第1页浏览型号AFL12015DZ/ES的Datasheet PDF文件第2页浏览型号AFL12015DZ/ES的Datasheet PDF文件第3页浏览型号AFL12015DZ/ES的Datasheet PDF文件第5页浏览型号AFL12015DZ/ES的Datasheet PDF文件第6页浏览型号AFL12015DZ/ES的Datasheet PDF文件第7页 
AFL120XXD Series  
Dynamic Characteristics -55°C < TCASE < +125°C, VIN=120V unless otherwise specified.  
Group A  
Parameter  
Subgroups  
Test Conditions  
Min  
Nom  
Max  
Unit  
LOAD TRANSIENT RESPONSE  
Note 2, 8  
AFL12005D  
Either Output  
Amplitude  
Recovery  
4, 5, 6  
4, 5, 6  
Load Step 50%  
100%  
-450  
-450  
450  
200  
mV  
µSec  
4, 5, 6  
4, 5, 6  
Load Step 10%  
50%  
50%  
10%  
450  
200  
400  
mV  
µSec  
µSec  
Amplitude  
Recovery  
10%  
50%  
4, 5, 6  
4, 5, 6  
Load Step 50%  
100%  
-750  
-750  
750  
200  
mV  
µSec  
AFL12012D  
Either Output  
Amplitude  
Recovery  
Amplitude  
Recovery  
4, 5, 6  
4, 5, 6  
Load Step 10%  
50%  
50%  
10%  
750  
200  
400  
mV  
µSec  
µSec  
10%  
50%  
4, 5, 6  
4, 5, 6  
Load Step 50%  
100%  
-750  
-750  
750  
200  
mV  
µSec  
AFL12015D  
Either Output  
Amplitude  
Recovery  
4, 5, 6  
4, 5, 6  
Load Step 10%  
50%  
50%  
10%  
750  
200  
400  
mV  
µSec  
µSec  
Amplitude  
Recovery  
10%  
50%  
Note 1, 2, 3  
LINE TRANSIENT RESPONSE  
V
Step = 80  
160 Volts  
-500  
500  
500  
mV  
µSec  
Amplitude  
Recovery  
IN  
TURN-ON CHARACTERISTICS  
Note 4  
Overshoot  
Delay  
4, 5, 6  
4, 5, 6  
Enable 1, 2 on. (Pins 4, 12 high or  
open)  
250  
120  
mV  
mSec  
50  
50  
75  
60  
LOAD FAULT RECOVERY  
LINE REJECTION  
Same as Turn On Characteristics.  
MIL-STD-461D, CS101, 30Hz to 50KHz  
Note 1  
dB  
Notes to Specifications:  
1. Parameters not 100% tested but are guaranteed to the limits specified in the table.  
2. Recovery time is measured from the initiation of the transient to where V  
at 50% load.  
has returned to within ±1% of V  
out  
out  
3. Line transient transition time 100 µSec.  
4. Turn-on delay is measured with an input voltage rise time of between 100 and 500 volts per millisecond.  
5. Current limit point is that condition of excess load causing output voltage to drop to 90% of nominal.  
6. Parameter verified as part of another test.  
7. All electrical tests are performed with the remote sense leads connected to the output leads at the load.  
8. Load transient transition time 10 µSec.  
9. Enable inputs internally pulled high. Nominal open circuit voltage 4.0VDC.  
10. Load current split equally between +V  
out  
and -V .  
out  
11. Output load must be distributed so that a minimum of 20% of the total output power is being provided by one of  
the outputs.  
12. Cross regulation measured with load on tested output at 20% of maximum load while changing the load on  
other output from 20% to 80%.  
4
www.irf.com  

与AFL12015DZ/ES相关器件

型号 品牌 获取价格 描述 数据表
AFL12015DZ/ESPBF INFINEON

获取价格

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, 0.380 INCH, LOW PROFILE, SEAM
AFL12015DZ/HB ETC

获取价格

DC to DC Converter
AFL12015DZ/HBPBF INFINEON

获取价格

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, 0.380 INCH, LOW PROFILE, SEAM
AFL12015DZ-CH INFINEON

获取价格

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
AFL12015DZES INFINEON

获取价格

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
AFL12015DZ-ES INFINEON

获取价格

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
AFL12015DZHB INFINEON

获取价格

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
AFL12015DZ-HB INFINEON

获取价格

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
AFL12015DZPBF INFINEON

获取价格

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, 0.380 INCH, LOW PROFILE, SEAM
AFL12015S INFINEON

获取价格

HIGH RELIABILITY HYBRID DC/DC CONVERTERS