Data Sheet
ADuM7640/ADuM7641/ADuM7642/ADuM7643
PACKAGE CHARACTERISTICS
Table 13.
Parameter
Symbol
RI-O
CI-O
CI
θJA
Min
Typ
1013
2
4.0
76
Max
Unit
Ω
pF
pF
°C/W
Test Conditions/Comments
Resistance (Input to Output)1
Capacitance (Input to Output)1
Input Capacitance2
f = 1 MHz
IC Junction-to-Ambient Thermal Resistance
Thermocouple located at
center of package underside
1 The device is considered a 2-terminal device: Pin 1 through Pin 10 are shorted together, and Pin 11 through Pin 20 are shorted together.
2 Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM7640/ADuM7641/ADuM7642/ADuM7643 are approved by the organizations listed in Table 14. See Table 18 and the
Insulation Lifetime section for recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 14.
UL (Pending)
Recognized Under UL 1577 Component Recognition Program1
Single Protection,1000 V rms Isolation Voltage
File E274400
1 In accordance with UL 1577, each ADuM7640/ADuM7641/ADuM7642/ADuM7643 is proof tested by applying an insulation test voltage ≥ 1200 V rms for 1 sec (current
leakage detection limit = 5 µA).
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 15.
Parameter
Symbol
Value
1000
3.8
Unit
Test Conditions/Comments
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
V rms
mm min
1 minute duration
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance path along body
L(I01)
L(I02)
Minimum External Tracking (Creepage)
2.8
mm min
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
2.6
>400
II
μm min
V
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
CTI
350
300
250
200
150
100
50
RECOMMENDED OPERATING CONDITIONS
Table 16.
Parameter
Symbol
Min
Max
+105
5.5
Unit
°C
V
Operating Temperature
Supply Voltages1
TA
−40
VDD1, VDD2 3.0
Input Signal Rise and Fall
Times
1.0
ms
1 All voltages are relative to their respective grounds. See the DC Correctness
section for information about immunity to external magnetic fields.
0
0
50
100
150
200
CASE TEMPERATURE (°C)
Figure 5. Thermal Derating Curve, Dependence of Safety-Limiting Values on
Case Temperature per DIN V VDE V 0884-10
Rev. 0 | Page 9 of 20