Fault Protection and Detection,
10 Ω RON, Quad SPST Switches
ADG5412F/ADG5413F
Data Sheet
FEATURES
FUNCTIONAL BLOCK DIAGRAMS
Overvoltage protection up to −55 V and +55 V
Power-off protection up to −55 V and +55 V
Overvoltage detection on source pins
Low on resistance: 10 Ω
ADG5412F
D1
D2
D3
D4
S1
S2
S3
S4
On-resistance flatness of 0.5 Ω
5.5 kV human body model (HBM) ESD rating
Latch-up immune under any circumstance
Known state without digital inputs present
FAULT
DETECTION
+ SWITCH
DRIVER
FF
V
SS to VDD analog signal range
5 V to 22 V dual supply operation
8 V to 44 V single-supply operation
Fully specified at 15 V, 20 V, +12 V, and +36 V
IN1 IN2 IN3 IN4
NOTES
1. SWITCHES SHOWN FOR A LOGIC 1 INPUT.
Figure 1. ADG5412F
APPLICATIONS
ADG5413F
Analog input/output modules
Process control/distributed control systems
Data acquisition
Instrumentation
Avionics
D1
D2
D3
D4
S1
S2
S3
S4
Automatic test equipment
Communication systems
Relay replacement
FAULT
DETECTION
+ SWITCH
DRIVER
FF
IN1 IN2 IN3 IN4
NOTES
1. SWITCHES SHOWN FOR A LOGIC 1 INPUT.
Figure 2. ADG5413F
GENERAL DESCRIPTION
The ADG5412F and ADG5413F contain four independently
controlled single-pole/single-throw (SPST) switches. The
ADG5412F has four switches that turn on with Logic 1 inputs.
The ADG5413F has two switches that turn on and two switches
that turn off with Logic 1 inputs. Each switch conducts equally
well in both directions when on, and each switch has an input
signal range that extends to the supplies. The digital inputs are
compatible with 3 V logic inputs over the full operating supply
range.
The low on resistance of these switches, combined with
on-resistance flatness over a significant portion of the signal
range make them an ideal solution for data acquisition and gain
switching applications where excellent linearity and low
distortion are critical.
PRODUCT HIGHLIGHTS
1. Source pins are protected against voltages greater than the
supply rails, up to −55 V and +55 V.
2. Source pins are protected against voltages between −55 V
and +55 V in an unpowered state.
3. Overvoltage detection with digital output indicates
operating state of switches.
4. Trench isolation guards against latch-up.
5. Optimized for low on resistance and on-resistance flatness.
6. The ADG5412F/ADG5413F can be operated from a dual
supply of 5 V up to 22 V or a single power supply of 8 V
up to 44 V.
When no power supplies are present, the switch remains in the off
condition, and the switch inputs are high impedance. Under
normal operating conditions, if the analog input signal levels on
any Sx pin exceed VDD or VSS by a threshold voltage, VT, the
switch turns off. Input signal levels up to +55 V or −55 V relative to
ground are blocked, in both the powered and unpowered
condition.
Rev. B
Document Feedback
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rightsof third parties that may result fromits use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks andregisteredtrademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 ©2014–2016 Analog Devices, Inc. All rights reserved.
Technical Support
www.analog.com