AD698
NOT ES
1A and B represent the Mean Average Deviation (MAD) of the detected sine waves VA and VB. T he polarity of VOUT is affected by the sign of the A comparator, i.e.,
multiply VOUT × +1 for ACOMP+ > ACOMP–, and VOUT × –1 for ACOMP– > ACOMP+
.
2Nonlinearity of the AD698 only in units of ppm of full scale. Nonlinearity is defined as the maximum measured deviation of the AD698 output voltage from a
straight line. T he straight line is determined by connecting the maximum produced full-scale negative voltage with the maximum produced full-scale positive voltage.
3See T ransfer Function.
4For example, if the excitation to the primary changes by 1 dB, the gain of the system will change by typically 100 ppm.
5Output ripple is a function of the AD698 bandwidth determined by C1 and C2. A 1000 pF capacitor should be connected in parallel with R2 to reduce the output
ripple. See Figures 7, 8 and 13.
6R1 is shown in Figures 7, 8 and 13.
7Excitation voltage drift is not an important specification because of the ratiometric operation of the AD698.
8From T MIN to T MAX the overall error due to the AD698 alone is determined by combining gain error, gain drift and offset drift. For example, the typical overall
error for the AD698AP from T MIN to T MAX is calculated as follows: Overall Error = Gain Error at +25°C (±0.2% Full Scale) + Gain Drift from –40°C to +25°C
(20 ppm/°C × 65°C) + Offset Drift from –40°C to +25°C (5 ppm/°C × 65°C) = ±0.36% of full scale. Note that 1000 ppm of full scale equals 0.1% of full scale.
Specifications subject to change without notice.
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tested are used to calculate outgoing quality levels.
All min and max specifications are guaranteed, although only those shown in boldface are tested on all production units.
CO NNECTIO N D IAGRAMS
28-P in P LCC
ABSO LUTE MAXIMUM RATINGS
T otal Supply Voltage (+VS to –VS) . . . . . . . . . . . . . . . . . 36 V
Storage T emperature Range
P Package . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to +150°C
Q Package . . . . . . . . . . . . . . . . . . . . . . . . –65°C to +150°C
Operating T emperature Range
4
3
2
1
28 27 26
AD698SQ . . . . . . . . . . . . . . . . . . . . . . . . –55°C to +125°C
AD698AP . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to +85°C
Lead T emperature Range (Soldering 60 sec) . . . . . . . . +300°C
Power Dissipation Derates above +65°C
P Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 mW/°C
Q Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 mW/°C
LEV1
LEV2
5
6
25 NC
24 SIG REF
FREQ1
FREQ2
NC
23
SIG OUT
7
AD698
TOP VIEW
(Not to Scale)
8
22 FEEDBACK
21 OUT FILT
20 AFILT1
9
BFILT1
BFILT2
10
11
TH ERMAL CH ARACTERISTICS
19 AFILT2
θJC
θJA
60°C/W
62°C/W
12
14 15 16 17 18
13
P Package 30°C/W
Q Package 26°C/W
NC = NO CONNECT
O RD ERING GUID E
24-P in Cerdip
Model
P ackage D escription
P ackage O ption
AD698AP
AD698SQ
28-Pin PLCC
24-Pin Double Cerdip
P-28A
Q-24A
–V
1
24
23
+V
S
S
EXC1
EXC2
2
3
OFFSET1
22 OFFSET2
21 SIG REF
LEV1
4
LEV2
5
20
19
18
17
SIG OUT
FEEDBACK
OUT FILT
AFILT1
AD698
TOP VIEW
(Not to Scale)
FREQ1
FREQ2
6
7
8
BFILT1
BFILT2
–BIN
9
16 AFILT2
10
11
12
15
14
–ACOMP
+ACOMP
+BIN
–AIN
13 +AIN
CAUTIO N
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD698 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. T herefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. B
–3–