A Dimensions: [mm]
B Recommended land pattern: [mm]
D1 Electrical Properties:
Properties
Capacitance
Rated voltage
Test conditions
1±0.2 Vrms, 1 kHz ±10%
Value
2200
50
Unit
pF
Tol.
± 10%
max.
typ.
C
U
V (DC)
R
Dissipation factor 1±0.2 Vrms, 1 kHz ±10%
DF
≤ 2.5%
≥ 10
Isolation Resistance Apply U for 120 s max.
R
GΩ
R
Iso
C Schematic:
E General information:
General Purpose MLCC
Ceramic Type:
X7R Class II
Temperature Coeffecient:
Storage Conditions:
Operating Temperature:
Dielectric Strength:
General Test conditions:
FIT according to
± 15% max.
35°C, <45% RH
-55 °C up to +125 °C
5 sec. @250% U ; Charge & Discharge Current < 50mA
R
25°C, 30-70% RH; if not specified differently
separate documentation
DESCRIPTION
Component Marking:
L ± 0.1
1.6
0.8
WCAP-CSGP Ceramic Capacitors
W ± 0.1
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
H +0.15/-0.10
E ± 0.15
0.8
Order.- No.
0.4
SIZE
A4
l - Reflow
2.30
0.70
0.80
l - Wave
p - Wave
w - Wave
2.40
1.00
0.80
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
885012206085
Size: 0603
1.0
2014-11-06
DATE
SSt
BY
PSL
p - Reflow
REV
CHECKED
w - Reflow
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.