A Dimensions: [mm]
B Recommended land pattern: [mm]
D1 Electrical Properties:
Properties
Capacitance
Rated voltage
Test conditions
1±0.2 Vrms, 1 kHz ±10%
Value
1500
50
Unit
pF
Tol.
± 10%
max.
typ.
C
U
V (DC)
R
Dissipation factor 1±0.2 Vrms, 1 kHz ±10%
DF
≤ 2.5%
≥ 10
Isolation Resistance Apply U for 120 s max.
R
GΩ
R
Iso
Precondition for Class II MLCC measurement: Apply a preheat treatment @150±10°C for 1 hour. The measurement
should be applied after 24±2 hrs the part was stored under ambient conditions. There is not any precondition necessary
for Class I MLCC.
C Schematic:
E General information:
General Purpose MLCC
Ceramic Type:
X7R Class II
Temperature Coeffecient:
Storage Conditions:
Operating Temperature:
Dielectric Strength:
General Test conditions:
FIT according to
± 15% max.
35°C, <45% RH
-55 °C bis +125 °C
5 sec. @250% U ; Charge & Discharge Current < 50mA
R
25°C, 30-70% RH; if not specified differently
separate documentation
DESCRIPTION
L ± 0.1
W ± 0.1
1.6
0.8
WCAP-CSGP Ceramic Capacitors
H +0.15/-0.10
E ± 0.15
0.8
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
0.4
Order.- No.
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
l - Reflow
2.30
0.70
0.80
l - Wave
p - Wave
w - Wave
2.40
1.00
0.80
SIZE
A4
p - Reflow
w - Reflow
885012206084
Size: 0603
1.0
2014-11-06
DATE
SSt
BY
PSL
REV
CHECKED
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.