Nexperia
74AUP1T14
Low-power inverter with voltage-level translator
Symbol Parameter
Conditions
Min
Typ
Max
Unit
Tamb = -40 °C to +125 °C
VT+
VT-
VH
positive-going threshold
voltage
VCC = 2.3 V to 2.7 V
0.60
0.75
0.33
0.46
-
-
-
-
1.10
1.19
0.64
0.85
V
V
V
V
VCC = 3.0 V to 3.6 V
negative-going threshold
voltage
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
hysteresis voltage
(VH = VT+ - VT-)
VCC = 2.3 V to 2.7 V
0.10
0.15
-
-
0.60
0.56
V
V
VCC = 3.0 V to 3.6 V
VOH
HIGH-level output voltage
VI = VT+ or VT-
IO = -20 μA; VCC = 2.3 V to 3.6 V
IO = -2.3 mA; VCC = 2.3 V
IO = -3.1 mA; VCC = 2.3 V
IO = -2.7 mA; VCC = 3.0 V
IO = -4.0 mA; VCC = 3.0 V
VI = VT+ or VT-
VCC - 0.11
1.77
-
-
-
-
-
-
-
-
-
-
V
V
V
V
V
1.67
2.40
2.30
VOL
LOW-level output voltage
IO = 20 μA; VCC = 2.3 V to 3.6 V
IO = 2.3 mA; VCC = 2.3 V
IO = 3.1 mA; VCC = 2.3 V
IO = 2.7 mA; VCC = 3.0 V
IO = 4.0 mA; VCC = 3.0 V
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.11
0.36
V
V
0.50
V
0.36
V
0.50
V
II
input leakage current
±0.75
±0.75
±0.75
μA
μA
μA
IOFF
ΔIOFF
power-off leakage current
additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
ICC
supply current
VI = GND or VCC; IO = 0 A;
VCC = 2.3 V to 3.6 V
-
-
3.5
μA
ΔICC
additional supply current
VCC = 2.3 V to 2.7 V; IO = 0 A
VCC = 3.0 V to 3.6 V; IO = 0 A
[1]
[2]
-
-
-
-
1.8
18
μA
μA
[1] One input at 0.3 V or 1.1 V, other input at VCC or GND.
[2] One input at 0.45 V or 1.2 V, other input at VCC or GND.
©
74AUP1T14
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2022. All rights reserved
Product data sheet
Rev. 3 — 25 January 2022