9 Recommended operating conditions
Table 6.ꢀRecommended operating conditions
Symbol Parameter
Conditions
Min
2.3
0
Max
3.6
Unit
V
VCC
VI
supply voltage
input voltage
output voltage
3.6
V
VO
Active mode
0
VCC
3.6
V
Power-down mode; VCC = 0 V
0
V
Tamb
ambient temperature
-40
+125
°C
10 Static characteristics
Table 7.ꢀStatic characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Tamb = 25 °C
Conditions
Min
Typ
Max
Unit
VT+
VT-
VH
positive-going threshold
VCC = 2.3 V to 2.7 V
0.60
0.75
0.35
0.50
-
-
-
-
1.10
1.16
0.60
0.85
V
V
V
V
voltage
VCC = 3.0 V to 3.6 V
negative-going threshold
voltage
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
hysteresis voltage
(VH = VT+ - VT-)
VCC = 2.3 V to 2.7 V
0.23
0.25
-
-
0.60
0.56
V
V
VCC = 3.0 V to 3.6 V
VOH
HIGH-level output voltage
VI = VT+ or VT-
IO = -20 μA; VCC = 2.3 V to 3.6 V
IO = -2.3 mA; VCC = 2.3 V
IO = -3.1 mA; VCC = 2.3 V
IO = -2.7 mA; VCC = 3.0 V
IO = -4.0 mA; VCC = 3.0 V
VI = VT+ or VT-
VCC - 0.1
2.05
1.9
-
-
-
-
-
-
-
-
-
-
V
V
V
V
V
2.72
2.6
VOL
LOW-level output voltage
IO = 20 μA; VCC = 2.3 V to 3.6 V
IO = 2.3 mA; VCC = 2.3 V
IO = 3.1 mA; VCC = 2.3 V
IO = 2.7 mA; VCC = 3.0 V
IO = 4.0 mA; VCC = 3.0 V
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.10
0.31
0.44
0.31
0.44
±0.1
±0.1
±0.1
V
V
V
V
V
II
input leakage current
μA
μA
μA
IOFF
ΔIOFF
power-off leakage current
additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
ICC
supply current
VI = GND or VCC; IO = 0 A;
VCC = 2.3 V to 3.6 V
-
-
1.2
μA
74AUP1T08
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2017. All rights reserved.
Product data sheet
Rev. 1 — 23 November 2017
4 / 15