General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay on DIN-rail SR6 Z
n
n
n
6 pole relay with force guided contacts according to EN50205
DIN rail mounting
AC / DC input
Typical applications
contact monitoring in railway, elevator and machine controls
F0238-C
Approvals
Other Data
relay SR6: VDE, UL, TUV, CQC
module SR6Z: CE
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
Technical data of approved types on request
Contact Data
Contact arrangement
for mounting/handling
in operation
0 to 40°C
-25 to 50°C
3 form A (NO) and 3 form B (NC),
4 form A (NO) and 2 form B (NC),
5 form A (NO) and 1 form B (NC)
SR6ZC 730 only
Terminal type
-25 to 40°C
screwless clamp connectors
Rated voltage
Max. switching voltage
Rated current
250VAC
250VAC
8A
Wire cross section
solid wire
stranded wire
stranded wire with bootlace crimp
Mounting position
Weight
2.5mm2
2.5mm2
1.5mm2
any
90g
2
Contact material
Contact style
AgSnO2,
single contact, force guided
type A according to EN 50205
5V, 10mA
Packaging unit
Min. recommended contact load
Initial contact resistance
≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Dimensions
Frequency of operation, with/without load
Contact ratings, IEC60947-5-1,
on 1 form A (NO) contact
6/150min-1
AC15-5A
DC13-6A
Mechanical endurance
10x106 operations
Coil Data
Coil voltage range
6 to 115 VAC/VDC,
230VAC
DC energizing voltage Urtd
AC/DC energizing voltage Urtd
AC energizing voltage Urtd
Operative range
6, 12, 18, 21, 24, 36, 40, 48, 60, 115VDC
24, 115VAC/VDC
230VAC
90 to 110% of Urtd
10% of Urtd
Release voltage (+23°C)
Max. coil power DC versions
Max. system power AC/DC versions
1200mW
2400mVA
S0423-A
Insulation Data
Module width 46 mm
Module length 87 mm
Fit onto mounting rails according to
DIN EN 60175
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Clearance/creepage
1000Vrms
3000Vrms
2000Vrms
between open contacts
between contact and coil
between adjacent contacts
microdisconnection
≥5.5/5.5mm
≥2,8 /2.8mm
Insulation to EN 50178, type of insulation
between contact and coil
between adjacent contacts
reinforced
basic
1
10-2012, Rev. 1012
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company