General Purpose Relays
Product Sets
SCHRACK
Relay Package PT
n
Relay package consisting of PT relay, DIN-rail socket, plastic
retaining clip, module and marking tag
2 pole 12 A, 3 pole 10 A or 4 pole 6 A
DC- or AC coil
nꢀ
nꢀ
nꢀ
nꢀ
Mechanical and electrical indicator
Manual test tab, optionally lockable
Approvals
Relay: VDE Cert. No. 40009108, cULus E214025, Lloyds 00/20059
F0274-D
Socket: VDE Cert. No. 40009108, cULus E135149
Technical data of approved types on request
Z
Contact data
PT2
2 CO
PT3
3 CO
single contact
micro disconnection
PT5
4 CO
Contact configuration
Contact set
Type of interruption
Rated voltage/
max. switching voltage AC
Rated current
Limiting continous current
Maximum breaking capacity AC
Limiting breaking capacity,
max. 20 ms
240/400VAC 240/400VAC 240/240VAC
12 A
3000 VA
24 A
10 A
see derating curve
2500 VA
6 A
1500 VA
12 A
20 A
Contact material
AgNi90/10, AgNi90/10 gold plated
12V/10mA, 20mV/1mA gold plated
Minimum contact load
Rated frequency of operation
with/without load
6 / 600 min-1
Contact ratings
For contact ratings see datasheet
Miniature Relay PT
Coil data
Rated coil voltage range
DC coil
AC coil
Operative range, IEC 61810
DC coil, AC coil 50 Hz
AC coil 60 Hz at 70°C
6...220 VDC
6...230 VAC
Insulation
PT2
PT3
PT5
Dielectric strength
2
coil-contact circuit
2500 Vrms
1200 Vrms
2500 Vrms
2500 Vrms
1200 Vrms
2500 Vrms
2500 Vrms
1200 Vrms
2000 Vrms
90...110% of rated voltage
open contact circuit
adjacent contact circuits
Clearance / creepage
coil-contact circuit
Coil versions, DC coil
≥ 4/4 mm
≥ 4/4 mm
≥ 4/4 mm
Coil
code
LED+PD*) VDC
Rated
voltage
Operate
voltage
VDC
9.0
18.0
Release
voltage
VDC
1.2
2.4
Coil
resistance
Ω 10%
192
Rated coil
power
mW
adjacent contact circuits
Material group of insulation parts
Insulation to IEC 60664-1
Type of insulation
≥3.5/9.5 mm ≥2.6/3.5 mm≥1.8/3.5 mm
IIIa
LB2
LC4
12
24
750
741
777
coil-contact circuit
basic
micro disconnection
basic
*) Protection diode PD
open contact circuit
adjacent cont. circuits
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
Coil versions, AC coil 50/60 Hz
Coil
code
LED
Rated
voltage
Operate
voltage
50/60 Hz
VAC
19.2/21.6
92.0/103.5 34.5
184.0/207.0 69.0
Release
voltage
50/60 Hz
VAC
Coil
resistance
Rated coil
power
50/60 Hz
VA
1.0/0.79
1.0/0.86
250 V
2
230/400 V
III
2
240 V
III
2
240 V
III
VAC
24
115
230
Ω
RC4
SB5
TD0
7.2
192 10%
4845 12%
19465 15% 1.0/0.90
All figures are given for coil without preenergization, at ambient temperature +23°C.
Other coil voltages on request.
1
04-2015, Rev. 0415
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company