6900 SSeerriieess 44 RRooww HHDDII CCoonnnneeccttoorr
Recommended Hole Size
Specifications
Insulator Material: Glass filled polyester, type PBT,
.040 .003 [1.02]
.0453 .001 [1.15]
94 V-O, UL Rated.
Contact Material: Copper Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
3 amp at 30°C
Contact Resistance:
Current Rating:
<
Insulation Resistance:
20m
.0040 [.10] min.
.0003 [.008] min.
12
>
10
m
at 100 VDC
Dielectric Strength:
<
1000 VDC
.001-.003 [.03-.08]
Dimensions are in inch [mm]
Compliant Section Insertion Force:
40 lbs max per contact
Compliant Section Withdrawal Force:
10 lbs min. per contact
Recommended Board Thickness:
.093”+
Operating Temperature:
-65BC to +125C
Hole
Diameter
Plating
Thickness
Pad
Diameter
Drilled Hole
Diameter
Copper
.001-.003 [.03-.08]
After Plating
.0453 .001
[1.15]
.065 [1.65]
.040 .003
[1.02]
Tin / Lead
.0003 [.008]min.
Current Range at
Ambient Temp. Of
+20C = 3 amp
+70C = 2 amp
= 1 amp
+100C
A
B
C
D
CONTACTS
100
120
128
60.96 [2.400]
73.66 [2.900]
78.74 [3.100]
64.77 [2.550]
77.47 [3.050]
82.55 [3.250]
74.93 [2.950]
87.63 [3.450]
92.71 [3.650]
82.55 [3.250]
95.25 [3.750]
100.33 [3.950]
140
160
180
86.36 [3.400]
99.06 [3.900]
111.76 [4.400]
90.17 [3.550]
102.87 [4.050]
115.57 [4.550]
100.33 [3.950]
113.03 [4.450]
125.73 [4.950]
107.95 [4.250]
120.65 [4.750]
133.35 [5.250]
200
220
240
124.46 [4.900]
137.16 [5.400]
149.86 [5.900]
128.27 [5.050]
140.97 [5.550]
153.67 [6.050]
138.43 [5.450]
151.13 [5.950]
163.83 [6.450]
146.05 [5.750]
158.75 [6.250]
171.45 [6.750]
260
280
162.56 [6.400]
175.26 [6.900]
166.37 [6.550]
179.07 [7.050]
176.53 [6.950]
189.23 [7.450]
184.15 [7.250]
196.85 [7.750]
CONNECTOR PERFORMANCE LEVELS
Level 1 (per DIN 41612 Part 5)
500 mating cycles
Level 2 (per DIN 41612 Part 5)
400 mating cycles
Level 3 (per DIN 41612 Part 5)
50 mating cycles
21 Days SO
250 mating Cycles
Measurement of contact resistance,
followed by visual inspection. Level
1 connectors show no abrasion of
the contact finish.
4 Days SO
200 mating Cycles
Measurement of contact resistance,
followed by visual inspection. Level
2 connectors show no abrasion of
the contact finish.
Visual Inspection (no gas test)
Measurement of contact resistance,
followed by visual inspection. Level
3 connectors show no abrasion of
the contact finish.
gas test
gas test
²
²
APPROVALS
CR
R
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E176234
ISO 9001:2000 registered
Bellcore GRE 1217 CORE
Connectors are available that meet the requirements of Bellcore GRE-1217-CORE. Please consult factory for ordering information.
ELECTRONIC CONNECTOR SERVICE INC. 11880 WESTERN AVE. STANTON, CA 90680 TOLL FREE (877) ECS-CONN TEL (714) 895-6351 FAX (714) 894-1858
WWW.ECSCONN.COM