60DAW_1.6 Series
60W - Single Output - Wide Input - Isolated & Regulated
DIP DC-DC Converter
DC-DC Converter
60 Watt
High efficiency up to 91%
2:1 wide input voltage range
Isolation voltage 1600VDC
Six-sided metal shield
Short circuit protection (SCP)
(automatic recovery)
Operating temperature:
The 60DAW_1.6 series offers 60W of output, 2:1 wide input voltage of
18-36VDC, 36-72VDC and features 1600VDC isolation, six-sided metal
shield over current and short circuit protection.
-40°C to +85°C
Over load protection
Over temperature protection
Industry standard pinout
Remote On/Off
All models are particularly suited to industry control systems,
semiconductor equipment, wireless network, telecom/datacom,
measurement etc.
Common specifications
Cooling:
Output specifications
Free air convection
Item
Test condition
Min Typ
Max
2
Units
%
Short circuit protection:
Operation temperature range:
Hiccup, auto-recovery
Voltage tolerance
-40°C~+85°C / refer to temperature
derating graph (with derating)
External trim adj.
range
of output
10
%
Storage temperature range:
Case temperature:
Lead temperature range:
Switching frequency:
Humidity:
-55°C~+125°C
Over load
protection
Input voltage range
150
%
+110°C
Line regulation
Load regulation
Ripple and noise
0.5
0.5
%
260°C MAX, 1.5mm from case for 10 sec
300kHz TYP
10%-100%
%
20MHz Bandwidth, 1.0µF
ceramic capacitor
100
mVp-p
non-condensing, 5%-95% MAX
Copper
Case material:
External trim adj.
range
10
%
Potting material:
MTBF (MIL-HDBK-217F @25°C):
Weight:
Epoxy (UL94V-0 rated)
>109,600 hours, Ground benign
48.6g
Transient response 25% load step change
setting time
250
µs
Dimensions:
50.8 x 25.4 x 13.1mm
50.8 x 25.4 x 17.8mm (with heatsink)
Isolation specifications
Item
Test condition
Test at 500VDC
Min
Typ
Max
Units
VDC
MΩ
Input specifications
Isolation voltage
Isolation resistance
Isolation capacitance
1600
Item
Test condition
Pi type
Min
Typ
Max
2:1
Units
1000
Voltage type
Filter
2200
pF
Protection
Fuse
recommended
Note:
1. Input voltage can’t exceed this value, or will cause the permanent damage.
2. The load shouldn‘t be less than 5%, otherwise ripple will increase dramatically.
3. Max. Capacitive Load is tested on Vin-nominal and full load.
4. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage
and rated output load unless otherwise specified.
Remote ON/OFF3)
• ON
• OFF
Open
Short to -Vin
5. In this datasheet, all the test methods of indications are based on corporate
standards.
Example:
60DAW_2415S1.6
60 = 60Watt; D = DIP; A = series; W = wide input (2:1) 18-36Vin;
15Vout; S = single output; 1.6 = 1600VDC
6. Only typical models listed, other models may be different, please contact our
technical person for more details.
7. Specifications subject to change without notice.
Page 1 of 2
60DAW_1.6 – Rev. 2020-1.0
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com