60ACPO_S Series
60W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
60 Watt
High efficiency up to 87%
Universal AC input range
(90~264VAC)
Over power protection (OPP)
Over voltage protection (OVP)
Over load protection (OLP)
Short circuit protection (SCP)
Wide operating ambient
temperature (-25°C~70°C)
All using 105°C long life
electrolytic capacitors
The 60ACPO_S series features standard rail mounting, energy efficiency
and is highly cost-effective. The series offers stability and high noise
immunity especially for industrial control equipment, machinery and
other demanding environments for industrial equipment. This converter
offers a compact and light weight design with and standard rail installati-
on (35mm). Furthermore this series offers Easy Fuse Tripping due and a
built-in DC OK relay contact. The converter can be installed on TS-35/7.5
or TS-35/15.
100% full load burn-in test
UL-60950-1 (E347551)
Common specifications
Short circut protection:
Temperature rise at full load:
Cooling:
Input specifications
Long-term mode, automatic recovery
50°C MAX
Input voltage range
Input frequency
AC current
90~264VAC
47~63Hz
<1.5A (max)
Free air convection
-25°C~+70°C
Inrush current
Cold start
<0.25mA
@120VAC
<30A (typ)
@230VAC
<60A (typ)
Operation temperature range:
Storage temperature range:
Storage humidity range:
Temperature coefficient:
MTBF (using MIL-HDBK-217F):
-0°C ~+85°C
Leakage current
< 95%
0.053%/°C MAX
+25°C >200,000 hours
MIL-217 Method 2 Components Stress
Method
Output specifications
Item
Test conditions
Full load
Min Typ
Max
0.5
Units
%
Safety standards:
Case material:
UL60950-1 2nd Ed; IEC 60950-1:2005 (2nd
Ed); EN60950-1:2006
Output voltage
accuracy
3
Heat-resistant Plastic (UL94-V0) and
metal
Voltage adjustment -5% ~ +10% of rated voltage
range
Dimensions (L*W*H):
Weight:
101.6×50.8×30mm
200g
Line regulation
Vin= min. to max. at
full load
%
Load regulation
Set-up time
0% to 100% load
2
1
%
s
@230VAC input, full
load
Isolation specifications
Item
Test condition
Min
Typ
Max
Units
VAC
Hold-up time
@230VAC input, full
load
20
ms
%
Withstand voltage
• Primary-secondary:
10mA
• Secondary PG: 10mA
3000
Overshoot and
undershoot
5
500
100
Isolation resistance
MΩ
Switching frequency
65
KHz
* Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated
with a 0.1 uF & 10uF parallel capacitor.
Protection specifications
Over-load
protection
105%~180% of rated
Protection type:
output current
Hiccup mode, auto recovery
Example:
Over-voltage
protection
105%~180% of rated
output voltage
Protection type:
Constant voltage, auto
recovery
60ACPO_24S
60 = 60Watt
AC = AC-DC
PO = series
24 = 24 Vout
S = single output
Over-power
protection
105%~180% of rated
output power
Protection type:
Hiccup mode, auto recovery
Note:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated
load and 25°C of ambient temperature.
Page 1 of 3
60ACPO_S – Rev. 2020-1.1
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG