High Performance Thermal-Magnetic Circuit Breaker 437-...
Description
Single pole high performance thermal-magnetic circuit breaker with
tease-free, trip-free, snap action mechanism and toggle actuation
(S-type TM CBE to EN 60934). Options include auxiliary contacts, a
moulded flame retardant enclosure for added environmental protection,
and remote operation - disconnection only, or disconnection and
re-connection. Also available in an IP65 housing (see type E-1032).
Typical applications
Battery and cable protection for all types of vehicles (including rail
vehicles and boats), battery powered systems.
1
437-...
Ordering information
Technical data
Type No.
437
single pole, toggle actuator
Terminal design
Voltage rating
DC 144 V
(higher voltage ratings upon request)
K12 flat screw terminals M10
K60 flat screw terminals DIN 46206, sheet 2, form 1, thread M10
Mounting
Current rating range
Auxiliary contact rating
40...240 A
(higher current ratings upon request)
1
5
lugs
brackets
6 A max. at DC 28 V
0.2 A at DC 180 V
Characteristic curve
06 fast trip
07 delayed trip
Electrical remote disconnection (-FA)
operating voltage
operating current
max. pulse time
switching time
DC 12 V or DC 24 V
Auxiliary contacts (blade terminals 6.3x08)
approx. 18 A or 12 A
10 ms < tON < 20 ms / tOFF > 10 s
< 20 ms
Si
one each N/O and N/C
Si01 one N/C (11/12), two N/O (13/14 + 23/24)
Si2 one N/O (13/14)
Remote trip (optional)
FA electrical remote disconnection
FC electrical remote disconnection (FA)
and re-connection (FE)
Coil voltage
Electrical remote re-connection (-FC)
operating voltage
operating current
max. pulse time
switching time
DC 12 V or DC 24 V
approx. 30 A or 15 A
0.1 s < tON < 1.2 s / tOFF > 60 s
< 100 ms
12 DC 12 V
24 DC 24 V
Typical life
3,000 operations at 240 A, DC 180 V
10,000 operations at 240 A, DC 28 V
20,000 operations mechanical
Current ratings
40...240 A
Ambient temperature
-40...+60 °C (-40...+140 °F)
Voltage ratings
(blank) ≤ DC 110 V
Insulation co-ordination
(IEC 60664 and 60664 A) withstand voltage
6 kV
rated impulse
pollution
degree
3
437 - K60 - 5 - 06 - Si01-FA 24 - 50A - ...
ordering example
Dielectric strength
(IEC 60664 and 60664 A) test voltage
operating area
main to aux. circuit
aux. circuits 11-12
to 13-14
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
AC 3,300 V
AC 2,200 V
Standard current ratings and typical internal resistance values
AC 1,000 V
Insulation resistance
> 100 MΩ (DC 500 V)
Current
Internal
Current
Internal
Interrupting capacity Icn
2,000 A at DC 180 V; L/R = 0 ms
10,000 A at DC 28 V; L/R = 0 ms
7,500 A at DC 28 V; L/R = 13 ms
rating (A)
resistance (Ω) rating (A)
resistance (Ω)
40
50
< 0.003
< 0.002
≤ 0.002
≤ 0.002
≤ 0.002
120
160
200
240
≤ 0.002
≤ 0.001
≤ 0.001
≤ 0.001
Degree of protection
(IEC 60529/DIN 40050)
operating area IP40,
terminal area IP00
with enclusure B IP54
with enclosure C IP65
63
Vibration
curve 06: 3 g (60-500 Hz), 0.23 mm (10-60 Hz)
curve 07: 4 g (60-500 Hz), 0.30 mm (10-60 Hz)
to IEC 60068-2-6, test Fc,
80
100
10 frequency cycles/axis
Shock
curve 06: 20 g (11 ms), to IEC 60068-2-27, test Ea
curve 07: 25 g (11 ms), to IEC 60068-2-27, test Ea
Corrosion
Humidity
Mass
48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-3, test Ca
approx. 900 g base unit
+ approx. 400 g remote re-connection
+ approx. 100 g remote disconnection
1646
www.e-t-a.de
1