General Purpose Relays
PCB Relays
SCHRACK
Miniature Power PCB Relay PB
n
n
n
n
n
1pole 10A, 1 form C (CO) or 1 form A (NO)
Environmentally-friendly cadmium-free contacts
Class F coil system standard
Compact and simple design gives high process security
Product in accordance to IEC 60335-1
Typical applications
White goods, small home appliances, heating temperature controllers
F0224-C
Z
V
Approvals
VDE REG.-Nr. 121560, UL E214025
Technical data of approved types on request
Coil Data
Coil voltage range
Operative range, IEC 61810
PB1
PB5
PB6
5 to 48 VDC 5 to 24 VDC 5 to 24 VDC
2
2
2
Contact Data
Coil versions, DC coil
Contact arrangement
Rated voltage
1 form C (CO) or 1 form A (NO)
Coil
code
Rated
voltage
VDC
Operate
voltage
VDC
Release
voltage
VDC
Coil
resistance
Ω 10%
Rated coil
power
mW
250VAC
400VAC
10A
Max. switching voltage
Rated current
Coil versions, DC-coil, 360mW
Limiting making current, max 4 s, duty factor 10% 15A
005
006
009
012
018
022
024
048
5
6
9
12
18
22
24
48
3.75
4.50
6.75
0.5
0.6
0.9
1.2
1.8
2.2
2.4
4.8
70
100
225
400
357
360
360
360
360
360
360
360
Breaking capacity max.
Contact material
Frequency of operation, with/without load
Operate/release time max.
Bounce time max., form A/form B
2500VA
AgNi 90/10, AgSnO2
360/36000h-1
10/20ms
9.00
13.50
16.50
18.00
36.00
900
10/15ms
1344
1600
6400
Contact ratings
Type
IEC 61810
PB114; PB113
PB114
PB134; PB133
PB134
Coil versions, DC-coil, 500mW
Contact
Load
Cycles
005
006
012
024
5
6
12
24
3.75
4.5
9
0.5
0.6
1.2
2.4
48
69
274
1097
521
522
526
525
A/B (NO/NC) 10A/3A, 250VAC, cosφ=1, 85°C 30x103
A of C
A (NO)
A (NO)
A (NO)
A (NO)
10A, 250VAC, cosφ=1, 85°C
10A, 250VAC, cosφ=1, 85°C
6.5A, 440VAC, cosφ=1, 85°C
8.5A, 250VAC, cosφ=1, 85°C
10A, 250VAC, cosφ=1, 85°C
30x103
20x103
50x103
100x103
60x103
18
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
PB634
PB634
UL 508
PB1x4
A (NO)
10A, 250VAC, cosφ=1, 85°C
20x103
Mechanical endurance, DC coil
5x106 operations
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
Clearance/creepage
1000Vrms
2500Vrms
between contact and coil
form C (CO) version
form A (NO) version
Material group of insulation parts
Tracking index of relay base
≥3/4mm
≥4/5mm
IIIa
PTI250
1
04-2011, Rev. 0411
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company