General Purpose Relays
SCHRACK
Power PCB Relay RZ
n
n
n
n
n
1 pole 12 / 16 A, 1 CO or 1 NO contact
DC-coil 400 mW
5 kV / 10 mm coil-contact, reinforced insulation
Ambient temperature 85°C, HOT version for 105°C
Product in accordance to IEC60335-1
Applications
Household appliances, boiler control, timers, garage door
control, POS automation
F0305-A
Approvals
V
REG.-Nr. C693,
Z
E214025
Technical data of approved types on request
Contact data
Contact configuration
1 CO or 1 NO contact
single contact
micro disconnection
250 / 400 VAC
Contact set
Type of interruption
Rated voltage / max. switching voltage AC
Rated current
Maximum breaking capacity AC
Contact material
Rated frequency of operation with / without load
Operate- / release time DC coil
Bounce time NO / NC contact
12 A
3000 VA
16 A
4000 VA
AgNi 90/10 or AgSnO
6 / 1200 min-1
max 8 / 6 ms
max 4 / 6 ms
Contact ratings
Type
Contact Load
Ambient
Cycles
temp. [°C]
IEC 61810
RZ03-1.4-D...
NO
16 A, 250 VAC
85°C
85°C
70°C
85°C
85°C
70°C
105°C
105°C
30x103
10x103
50x103
50x103
30x103
100x103
100x103
10x103
RZ03-1C4-D... CO
16 A, 250 VAC
16 A, 250 VAC
12 A, 250 VAC
12 A, 250 VAC
12 A, 250 VAC
10 A, 250 VAC
16 A, 250 VAC
RZ03-1.4-D...
RZ01-1.4-D...
NO
NO
RZ01-1C4-D... CO
RZ01-1.4-D...
RZH3-1.4-D...
RZH3-1C4-D... CO
UL 508
NO
NO
RZ03-1.4-D...
RZ03-1.4-D...
RZ03-1.4-D...
RZ03-1.4-D...
RZH3-1.4-D...
NO
NO
NO
NO
NO
B300
85°C
85°C
85°C
85°C
105°C
6x103
6x103
R300
1/2 hp, 125 VAC
1 hp, 277 VAC
10 A, 250 VAC
6x103
6x103
150x103
Approvals in process
RZ03-1.3-D...
RZ03-1.3-D...
RZ03-1.3-D...
NO
CO
NO
16 A, 250 VAC
16 A, 250 VAC
1 hp, 277 VAC
85°C
85°C
85°C
50x103
10x103
30x103
Coil data
Rated coil voltage range
5...48 VDC
Operative range to IEC 61810 standard / HOT-version
Coil insulation system according UL1446
2 / 90...110% URTD
class F
1
Datasheet Rev. IK1
Issued 2009/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information only