General Purpose Relays
PCB Relays
Potter & Brumfield
Power PCB Relay RT1
n
n
n
n
1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact
Sensitive coil 400mW
5kV/10mm coil-contact, reinforced insulation
Ambient temperature 85°C
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules
V Z b
Approvals
VDE REG.-Nr. 6106, UL E214025, cCSAus 14385
Technical data of approved types on request
Contact Data (continued)
Contact ratings
Type
Load
Cycles
6x103
6x103
6x103
Contact Data
12A
16A
RT3, RTD
RT3, RTD
RT3, RTD
RT3, RTD
RT3, RTD
RT3, RTD
RT3, RTD
1 HP @ 480VAC* motor
1 HP @ 240VAC* motor
1/2 HP @ 120VAC* motor
60 LRA/10 FLA @ 250VAC* motor
TV-5 @ 120VAC* Tungsten
A300, 720VA @ 240VAC* Pilot Duty
B300, 360VA @ 240VAC** Pilot Duty
Contact arrangement
1 form C (CO) or 1 form A (NO)
Rated voltage
Max. switching voltage
Rated current
250VAC
400VAC
30x103
25x103
30x103
30x103
12A
12A
16A
16A, UL: 20A
Limiting continuous current
Limiting making current
max. 4s, duty factor 10%
Breaking capacity max.
Contact Material
Frequency of operation, with/without load
Operate/release time max., DC coil
Bounce time max., DC coil, form A/form B
*) form A (NO) contact only, **) form B (NC) contact only
25A
3000VA
30A
4000VA
AgNi 90/10
Mechanical endurance
>30x106 operations
360/72000h-1
8/6ms
4/6ms
Coil Data
Coil voltage range
5 to 110VDC
Contact ratings
Operative range, IEC 61810
Coil insulation system according UL
2
Type
Contact
Load
Cycles
class F
IEC 61810
RT314 DC-coil A (NO)
RT314 DC-coil C (CO)
RT314 DC-coil A (NO)
RT114 DC-coil A (NO)
RT114 AC-coil A (NO)
UL 508
RT314
RT334
RT314
EN60947-5-1
16A, 250VAC, cosφ=1, 85°C
16A, 250VAC, cosφ=1, 85°C
10A, 400VAC, cosφ=1, 85°C
12A, 250VAC, cosφ=1, 85°C
12A, 250VAC, cosφ=1, 70°C
30x103
10x103
Coil versions, DC coil
Coil
code
Rated
voltage
VDC
5
Operate
voltage
VDC
3.5
Release
voltage
VDC
0.5
Coil
resistance
Ω 10%
62
Rated coil
power
mW
150x103
50x103
100x103
005
006
009
012
024
048
403
400
6
9
4.2
0.6
90
A/B (NO/NC) 20A, 250VAC, general purpose, 85°C 6x103
6.3
8.4
0.9
1.2
200
360
400
400
A (NO)
A (NO)
16A, 250VAC, gen. purpose, 85°C
1hp, 240VAC, 40°C
50x103
1x103
12
24
48
16.8
33.6
2.4
4.8
1440
5520
400
417
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
RT314 DC-coil A/B (NO/NC) 2A, 24VDC, DC13
6.050
EN60730-1
RT314 DC-coil A (NO)
12(2)A, 250VAC, 85°C
100x103
1
04-2011, Rev. 0411
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company