5秒后页面跳转
2038-47-SM-RP2 PDF预览

2038-47-SM-RP2

更新时间: 2024-09-18 00:43:55
品牌 Logo 应用领域
伯恩斯 - BOURNS 局域网二极管
页数 文件大小 规格书
3页 242K
描述
Miniature Symmetrical 3-Electrode Surface Mount Gas Discharge Tube

2038-47-SM-RP2 技术参数

生命周期:Active包装说明:O-LELF-R2
针数:2Reach Compliance Code:unknown
ECCN代码:EAR99HTS代码:8541.10.00.50
风险等级:5.76外壳连接:ISOLATED
配置:SINGLE二极管元件材料:SILICON
二极管类型:TRANS VOLTAGE SUPPRESSOR DIODEJESD-30 代码:O-LELF-R2
元件数量:1端子数量:2
封装主体材料:GLASS封装形状:ROUND
封装形式:LONG FORM极性:UNIDIRECTIONAL
认证状态:Not Qualified表面贴装:YES
技术:AVALANCHE端子形式:WRAP AROUND
端子位置:ENDBase Number Matches:1

2038-47-SM-RP2 数据手册

 浏览型号2038-47-SM-RP2的Datasheet PDF文件第2页浏览型号2038-47-SM-RP2的Datasheet PDF文件第3页 
Features  
nꢀ Highꢀsurgeꢀcurrentꢀrating,ꢀlowꢀinsertionꢀlossꢀ  
nꢀ Stableꢀbreakdownꢀthroughoutꢀlifeꢀ  
nꢀ BalancedꢀMini-TRIGARD™ꢀꢀ  
(5ꢀmmꢀdiameter,ꢀ7.5ꢀmmꢀlength)ꢀ  
nꢀ Idealꢀforꢀboardꢀlevelꢀprotectionꢀofꢀꢀ  
broadbandꢀcircuitsꢀ  
nꢀ RoHSꢀcompliant*ꢀversionsꢀavailable  
nꢀ Symmetricalꢀbreakdownꢀvoltageꢀ(L-L,ꢀL-G)  
nꢀ Leadless,ꢀsurfaceꢀmountꢀforꢀeconomicalꢀꢀ  
assemblyꢀ  
ꢀꢀ2038ꢀSeriesꢀMiniatureꢀSymmetricalꢀ3-ElectrodeꢀSurfaceꢀMountꢀGasꢀDischargeꢀTube  
Bourns offers a symmetrical surface mount (SM) 3-electrode GDT surge protection device. The industry-leading quality and features of the  
Bourns® miniature-TRIGARDTM series GDT continue in the 2038 symmetrical version. The 2038 series is ideal for board level protection of  
high bandwidth applications such as xDSL, cable broadband and high speed Ethernet, due to its symmetrical turn on characteristics as well as  
high energy-handling capability, long and stable life performance and low capacitance of less than 1 pF. The 2038 series breakdown  
voltages are nearly equal line to line as well as line to ground. Bourns® Gas Discharge Tubes (GDT) are designed to prevent damage from  
transient disturbances by acting as a “crowbar” in creating a virtual short-to-ground circuit during conduction. When an electrical surge  
exceeds the defined breakdown voltage level of the GDT, the gas becomes ionized and rapid conduction takes place. When the surge passes  
and the system voltage returns to normal levels, the GDT returns to its high-impedance (off) state.  
Characteristics  
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.  
Model No.  
2038-23-SM  
Characteristic  
2038-15-SM  
2038-20-SM  
2038-30-SM  
2038-35-SM  
DC Sparkover ± 25 % @ 100 V/s  
150 V  
200 V  
230 V  
300 V  
350 V  
L1/L2 to Gnd (1)  
Typical Impulse Sparkover (2)  
L1/L2 to Gnd  
100V/μs  
1000V/μs  
350 V  
500 V  
425 V  
575 V  
450 V  
600 V  
500 V  
650 V  
600 V  
750 V  
Model No.  
2038-60-SM  
Characteristic  
2038-42-SM  
2038-47-SM  
2038-80-SM  
2038-110-SM  
DC Sparkover ± 25 % @ 100 V/s  
420 V  
470 V  
600 V  
800 V  
1100 V  
L1/L2 to Gnd (1)  
Typical Impulse Sparkover (2)  
L1/L2 to Gnd  
100V/μs  
1000V/μs  
675 V  
850 V  
750 V  
950 V  
850 V  
1100 V  
1150 V  
1400 V  
1500 V  
1700 V  
(2)  
Impulse Sparkover voltage is defined as typical values of distribution.  
Impulse Transverse Delay............................... 100 V/µs............................................................< 50 ns  
9
Insulation Resistance (IR) ............................... 100 V ................................................................> 10 Ω  
Glow Voltage ................................................... 10 mA................................................................~ 70 V  
Arc Voltage...................................................... 1 A.....................................................................~ 10 V  
Glow-Arc Transition Current.......................................................................................................< 0.5 A  
Capacitance..................................................... 1 MHz ...............................................................< 1 pF  
DC Holdover Voltage (3) ................................... 135 V (80 V for Model 2038-15) .......................< 150 ms  
Impulse Discharge Current.............................. 10000 A, 8/20 µs (4) ...........................................1 operation min.  
5000 A, 8/20 µs.................................................> 10 operations  
200 A, 10/1000 µs.............................................> 300 operations  
200 A, 10/700 µs ..............................................> 500 operations  
10 A, 10/1000 µs ..............................................> 1500 operations  
Alternating Discharge Current......................... 10 Arms, 1 s (4) ..................................................1 operation min.  
5 Arms, 1 s........................................................> 10 operations  
Operating Temperature............................................................................................................... -40 to +90 °C  
Climatic Category (IEC 60068-1)................................................................................................ 40/90/21  
Notes:  
• 2038-35 UL Recognized  
, file E153537, 2038-110 CSA Approved  
, file LR93265 (UL 1449).  
• The rated discharge current for Mini-TRIGARD™ GDTs is the total current equally divided between each line to ground.  
• Surface Mount (SM) parts may show a temporary increase in DCBD after the solder reflow process. Most devices will recover within 24 hours  
time. It should be noted that there is no quality defect nor change in protection levels during the temporary change in DCBD.  
8
• Sparkover limits after life ±30 %. IR >10 Ω.  
• Operating characteristics per RUS PE-80 and Telcordia GR 1361 available on request.  
• At delivery AQL 0.65 Level II, DIN ISO 2859.  
• Bourns recommends reflowing surface mount devices per IPC/JEDEC J-STD-020 rev D.  
(1) Line to Line DC Sparkover tolerance typically less than +30 % at 100 V/s.  
(3) Network applied.  
(4) DC Sparkover may exceed ±30 % but will continue to protect without venting.  
*RoHSꢀDirectiveꢀ2002/95/ECꢀJan.ꢀ27,ꢀ2003ꢀincludingꢀannexꢀandꢀRoHSꢀRecastꢀ2011/65/EUꢀJuneꢀ8,ꢀ2011.ꢀ  
Specificationsꢀareꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.  
Theꢀdeviceꢀcharacteristicsꢀandꢀparametersꢀinꢀthisꢀdataꢀsheetꢀcanꢀandꢀdoꢀvaryꢀinꢀdifferentꢀapplicationsꢀandꢀactualꢀdeviceꢀperformanceꢀmayꢀvaryꢀoverꢀtime.  
Usersꢀshouldꢀverifyꢀactualꢀdeviceꢀperformanceꢀinꢀtheirꢀspecificꢀapplications.  

与2038-47-SM-RP2相关器件

型号 品牌 获取价格 描述 数据表
2038-47-SM-RP2LF BOURNS

获取价格

Miniature Symmetrical 3-Electrode Surface Mount Gas Discharge Tube
2038-47-SM-RP2-LF BOURNS

获取价格

UNIDIRECTIONAL, SILICON, TVS DIODE, ROHS COMPLIANT, MINIATURE PACKAGE-2
2038-47-SM-RPLF BOURNS

获取价格

Trans Voltage Suppressor Diode, Unidirectional, 1 Element, Silicon, ROHS COMPLIANT, MINIAT
2038-47-SM-RP-LF BOURNS

获取价格

UNIDIRECTIONAL, SILICON, TVS DIODE, ROHS COMPLIANT PACKAGE
2038-60-SM BOURNS

获取价格

2038 Series Miniature Symmetrical 3-Electrode Surface Mount Gas Discharge Tube
2038-60-SMLF BOURNS

获取价格

UNIDIRECTIONAL, SILICON, TVS DIODE, ROHS COMPLIANT, MINIATURE PACKAGE-2
2038-60-SM-LF BOURNS

获取价格

Miniature Symmetrical 3-Electrode Surface Mount Gas Discharge Tube
2038-60-SM-RP BOURNS

获取价格

Trans Voltage Suppressor Diode, Unidirectional, 1 Element, Silicon, MINIATURE PACKAGE-2
2038-60-SM-RP2 BOURNS

获取价格

Trans Voltage Suppressor Diode, Unidirectional, 1 Element, Silicon, MINIATURE PACKAGE-2
2038-60-SM-RP2LF BOURNS

获取价格

Trans Voltage Suppressor Diode, Unidirectional, 1 Element, Silicon, ROHS COMPLIANT, MINIAT