描述
Protection of electrical systems of passenger cars, trucks, buses, watercraft, extra low voltage wiring systems

1620-3-30A 数据手册

 浏览型号1620-3-30A的Datasheet PDF文件第2页 
Thermal automotive Mini-CBE 1620-...  
Description  
Single pole, thermal miniaturised circuit breaker designed for automotive  
applications. Fits into fuse blocks designed to ISO 8820-3, Type F.  
Automatic reset (for DC 12 V only) and open circuit (modified reset to  
SAE) version optional. Open circuit version ensures contacts staying  
open as long as power is on. The circuit breaker will reset after the  
load is removed. Particularly suitable for installation in inaccessible  
locations.  
Current ratings correspond to those of blade fuses. Clear colour  
coding of the ratings: blade fuse and circuit breaker of the same colour  
have the same rating.  
1
Meets the requirements of SAE J553.  
1620-1/-2  
1620-3  
1620-3H  
US patent number: US 8,576,042,B2  
Technical data  
Typical applications  
Voltage rating  
1620-1/-2: DC 12 V  
1620-3/-3H: DC 12 V, DC 24 V  
1620-1/-2: DC 14.5 V  
1620-3/-3H: DC 29.0 V  
DC 12 V: 5...30 A  
Protection of electrical systems of passenger cars, trucks, buses,  
watercraft, extra low voltage wiring systems.  
Max. voltage rating  
Current ratings  
DC 24 V: 5...25 A  
Ordering information  
Service short-circuit  
breaking capacity  
300 operations at 2 x IN  
Type No.  
Ambient temperature  
-40...+85 °C (-40…+185 °F)  
(for higher temperatures please enquire)  
1620 single pole thermal Mini-CBE with standard characteristic curve  
Version, according to SAE J553  
Reset period for 1620-1  
(at 23 °C)  
1
2
3
type 1, DC 12 V automatic reset  
type 2, DC 12 V modified reset  
type 3, DC 24 V with reset button  
≤ 15 s  
< 35 s  
Reset period for 1620-2  
(at 23 °C) after 5 sec at  
rated voltage  
3H type 3*, DC 24 V with reset button and manual release facility  
Current ratings  
5
7.5  
10  
15  
20  
25 30 A  
Degree of protection  
(IEC 60529)  
operating area IP40 (-3)  
operating area IP50 (-1, -2)  
terminal area IP00  
1620 - 1 - 10 A ordering example  
Ultimate short-circuit  
breaking capacity  
Current ratings, typical voltage drop values and colour coding  
≥ 3 break operations at 150 A, or  
≥ 1 break operation at 2,000 A  
Current rating (A)  
Voltage drop (mV) Housing cap colour  
Vibration  
10 g (57-500 Hz), 0.38 mm (10-57 Hz)  
to IEC 60068-2-6, test Fc  
10 frequency cycles/axis  
5
< 150  
< 150  
< 150  
< 150  
< 150  
< 150  
< 150  
light brown  
brown  
red  
SAE-J553, Step No. 14, § 4.2.7.1.5  
7.5  
10  
15  
20  
25  
30  
Shock  
50 g (11 ms)  
to IEC 60068-2-27, test Ea  
SAE-J553, Step No. 14, § 4.2.7.1.6  
blue  
Corrosion  
Humidity  
24 hrs in 5 % salt mist,  
to IEC 60068-2-11, test Ka  
SAE-J553, Step No. 14, § 4.2.7.1.3  
yellow  
white  
240 hrs in 95 % RH,  
to IEC 60068-2-78, test Cab  
SAE-J553, Step No. 14, § 4.2.7.1.2  
light green  
Mass  
approx. 3 g  
Caution:  
It is good practice to switch off the vehicle’s ignition system before  
manually releasing or re-setting the circuit breaker. Free travel of the  
reset button must be ensured! Please ensure to push in the actuator  
smoothly and completely.  
Depending on the socket used and with the 30 A device carrying a  
full load, the temperatures at the terminals may rise above the allowed  
SAE value.  
1646  
www.e-t-a.de  
1

与1620-3-30A相关器件

型号 品牌 获取价格 描述 数据表
1620337 PHOENIX

获取价格

K-7E - OE/5 0-D04/M40 F8
1620338 PHOENIX

获取价格

K-7E - OE/010-D04/M40 F8
1620339 PHOENIX

获取价格

K-7E - OE/2 0-D05/M40 F8
1620342 PHOENIX

获取价格

K-7E - OE/2 0-D06/M40 F8
1620343 PHOENIX

获取价格

K-7E - OE/5 0-D06/M40 F8
1620344 PHOENIX

获取价格

K-7E - OE/010-D06/M40 F8
1620346 PHOENIX

获取价格

K-5E-M40 M9/5 0-C03/M40 F8
1620347 PHOENIX

获取价格

K-5E-M40 M9/010-C03/M40 F8
1620349 PHOENIX

获取价格

K-5E-M40 M9/5 0-C04/M40 F8
1620-3-5A ETAL

获取价格

Protection of electrical systems of passenger cars, trucks, buses, watercraft, extra low v