F
E
D
C
B
A
b
NOTES:
n1,12 (15x)
1. RECOMMENDED SOLDER INSTRUCTION SEE SHEET 2
2. IP RATING: IP 67
3. SEALED TO WITHSTAND PRESSURE UP TO 1,45 PSI
FOR 30 MINUTES AFTER SOLDERING
4. METALSHELL: ZINC DIE CAST; min. 50µin NICKEL PLATING over COPPER
5. INSULATORS: PBT GF UL 94 V-0, BLACK
( 5 : 1 )
D
6. O-RING: SILICONE PER ASTM D2000 70 SHORE A
7. RUBBER GASKET: TPE
D
8. SEALING COMPOUND: EPOXY RESIN UL 94 V-0; BLACK
9. CONTACTS: COPPER ALLOY
PLATING (SEE PART NO):
o PLEASE ADD 1 for 30µin HARD GOLD over min. 50µin NICKEL
o PLEASE ADD 3 for 8µin HARD GOLD over min. 50µin NICKEL
SOLDER CUP ACCEPTS CABLE AWG 20
10. HEXLOCKING SCREWS: STAINLESS STEEL
11. RECOMMENDED PANEL CUT-OUT ON SHEET 2
12. RECOMMENDED TORQUE FOR MOUNTING SCREW
35Ncm (3.1 in.LB) / max.67Ncm (6 in.LB)
c
13. CONNECTOR IS PART MARKED: 15-00058o CONEC ABC
0,25
8,23+-
0
0,3
0
47,7 +-
33,32 +-
25,14 +-
c
RUBBER GASKET
0,13
0,12
PLACED ON TOP SURFACE
OF MALE INSULATOR
C
C
POS. 1
POS. 9
0,23
0,02
SEALING
COMPOUND
15-00058o
O-RING
B
B
CONEC ABC
4-40 UNC
b
SEE NOTE 13
SW 4,8
4-40 UNC
c
AT ALL TIMES WATER RESISTANT CONNECTORS NOT
IN USE SHOULD BE COVERED WITH A CONEC WATER
RESISTANT CAP OR WATER TIGHT HOOD.
APPROVAL # FREIGABE # DEBLOCAGE # AUTORIZACION # APPROVAL
CUSTOMER APPROVAL DATE:
2:1 (5:1)
scale:
material:
tolerance
see notes
dim. in mm
A
A
date
name
title:
drawn
03.09.08
15.09.08
Schmidt
Fischer
D-SUB MALE
15pos. SOLDER CUP
with hexlocking screw
NAME:
TITLE:
appd.
norm
d-old
dwg no:
3 x c
3 x b
a
29.09.09
26.09.08
HS
HS
Ä 3435
Inventor 10
DIN-
A3
sh: 1
COMPANY NAME:
Ä 3129
Origin
R
15K1A261
APPROVAL # FREIGABE # DEBLOCAGE # AUTORIZACION # APPROVAL
rev. description
D
name
part no:
date
15-00058o (see note 9)
b
F
E
C
B
A