F
E
D
C
B
A
b
NOTES:
n1,04 (26x)
1. RECOMMENDED SOLDER INSTRUCTION SEE SHEET 2
2. IP RATING: IP 67
3. SEALED TO WITHSTAND PRESSURE UP TO 1,45 PSI
FOR 30 MINUTES AFTER SOLDERING
4. METALSHELL: ZINC DIE CAST; min. 50µin NICKEL PLATING over COPPER
5. INSULATORS: PBT GF UL 94 V-0, BLACK
( 5 : 1 )
D
D
6. O-RING: SILICONE PER ASTM D2000 70 SHORE A
7. RUBBER GASKET: TPE
8. SEALING COMPOUND: EPOXY RESIN UL 94 V-0; BLACK
9. CONTACTS: COPPER ALLOY
PLATING (SEE PART NO):
o PLEASE ADD 1 for 30µin HARD GOLD over min. 50µin NICKEL
o PLEASE ADD 3 for 8µin HARD GOLD over min. 50µin NICKEL
SOLDER CUP ACCEPTS CABLE AWG 22
10. HEXLOCKING SCREWS: STAINLESS STEEL
11. RECOMMENDED PANEL CUT-OUT ON SHEET 2
12. RECOMMENDED TORQUE FOR MOUNTING SCREW
35Ncm (3.1 in.LB) / max.67Ncm (6 in.LB)
c
13. CONNECTOR IS PART MARKED: 15-00066o CONEC ABC
0,25
0
8,23+-
0,3
47,7 +-
c
0
POS. 1
RUBBER GASKET
0,13
33,32 +-
PLACED ON TOP SURFACE
OF MALE INSULATOR
C
0,12
C
POS. 10
0,23
25,14 +- 0,02
POS. 19
SEALING
COMPOUND
15-00066o
O-RING
B
B
CONEC ABC
4-40 UNC
b
SEE NOTE 13
SW 4,8
4-40 UNC
c
AT ALL TIMES WATER RESISTANT CONNECTORS NOT
IN USE SHOULD BE COVERED WITH A CONEC WATER
RESISTANT CAP OR WATER TIGHT HOOD.
APPROVAL # FREIGABE # DEBLOCAGE # AUTORIZACION # APPROVAL
2:1 (5:1)
scale:
tolerance
CUSTOMER APPROVAL DATE:
material:
see notes
dim. in mm
A
A
date
name
title:
drawn
11.09.08
15.09.08
Schmidt
Fischer
D-SUB MALE HD
26pos. SOLDER CUP
with hexlocking screw
NAME:
TITLE:
appd.
norm
d-old
dwg no:
3 x c
3 x b
a
01.10.09
HS
Ä 3435
Inventor 10
DIN-
A3
sh: 1
COMPANY NAME:
26.09.08 Petker
Ä 3129
Origin
R
15K1A272
APPROVAL # FREIGABE # DEBLOCAGE # AUTORIZACION # APPROVAL
rev. description
D
name
part no:
date
15-00066o (see note 9)
b
F
E
C
B
A