136D
Vishay
www.vishay.com
Wet Tantalum Capacitors Tantalum-Case with Glass-to-Tantalum
Hermetic Seal for -55 °C to +125 °C Operation, Low ESR
FEATURES
• Military specification MIL-PRF-39006/30 and
39006/31. model 136D capacitors are
commercial equivalents of military style
Available
CLR90 and CLR91
Available
• Capacitors to meet the MIL-specs must be
ordered by M39006 part numbers shown in
the relative specification
Available
• Axial through-hole terminations: standard tin /
lead (SnPb), 100 % tin (RoHS-compliant) available
• Standard and extended ratings
• Low ESR
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
Note
*
This datasheet provides information about parts that are
RoHS-compliant and / or parts that are non-RoHS-compliant. For
example, parts with lead (Pb) terminations are not RoHS-compliant.
Please see the information / tables in this datasheet for details.
PERFORMANCE CHARACTERISTICS
Operating Temperature: -55 °C to +85 °C
Following life test:
(to +125 °C with voltage derating)
1. DCL, measured at +85 °C rated voltage, shall not be in
excess of the original requirement.
Capacitance Tolerance: at 120 Hz, +25 °C.
20 %
standard. 10 %, 5 % available as special.
2. The equivalent series resistance shall not exceed 150 %
of the initial requirement.
DC Leakage Current (DCL Max.): at +25 °C and above:
leakage current shall not exceed the values listed in the
Standard Ratings Tables.
3. Change in capacitance shall not exceed 10 % from the
initial measurement.
Life Test: capacitors are capable of withstanding a 2000 h
life test at a temperature of +85 °C or +125 °C at the
applicable rated DC working voltage.
ORDERING INFORMATION
136D
306
X0
006
C
2
E3
MODEL
CAPACITANCE
CAPACITANCE
TOLERANCE
DC VOLTAGE RATING
AT +85 °C
CASE CODE
STYLE NUMBER
RoHS-
COMPLIANT
This is expressed
in picofarads. The
first two digits
are the significant
figures. The third
is the number of
zeros to follow
X0 = 20 %
X9 = 10 %
X5 = 5 %
This is expressed in
volts. To complete the
three-digit block, zeros
precede the voltage
rating. A decimal point
is indicated by an “R”
(6R3 = 6.3 V)
See Ratings
and Case
Codes table
Std. temperature
(max. +125 °C)
0 = no insulating
sleeve
E3 = 100 % tin
termination
(RoHS-compliant
design)
Blank = SnPb
termination
(standard
2 = polyester
insulation sleeve
3 = high temperature
film insulation
design)
Note
•
Packaging: the use of formed plastic trays for packaging these axial lead components is standard. Tape and reel is not available due to the
unit weight.
Revision: 05-Dec-14
Document Number: 40132
1
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000