High Temperature – Very Low ESR – High Ripple Current –
Stable with Temperature – High Frequency
FEATURES
DC-DC Converters – Voltage Regulators – Decoupling
APPLICATIONS
Operating Temperature Range
Capacitance Tolerance
-55°C to +105°C
+20% at 120 Hz, 20°C
WVDC
SVDC
2.5
4
10
16
Surge Voltage
1.15 x rated WVDC
Dissipation Factor
120 Hz, 20°C
10% MAX
2 Minutes
0.2CV or 280uA, whichever is greater
Leakage Current
Low Temperature
-55°C/ +20°C
<1.25
<1.25
Stability
Impedance Ratio
(100 kHz)
+105°C/ +20°C
5000 hours at 105°C with rated WVDC applied
<20% of initial measured value
Capacitance Change
Dissipation Factor
ESR
<150% of maximum specified value
<150% of maximum specified value
<100% of maximum specified value
Load Life
Leakage Current
1000 hours at 60°C with rated voltage applied at 90-95% R.H.
Capacitance Change
<20% of initial measured value
Dissipation Factor
ESR
<150% of maximum specified value
<150% of maximum specified value
<100% of maximum specified value
Damp Heat test
Leakage Current
1000 cycles at 105°C with rated surge voltage applied for 30 seconds through a 1kΩ resistor
and discharged for 5 minutes and 30 seconds
Capacitance Change
Dissipation Factor
ESR
<20% of initial measured value
<150% of maximum specified value
<150% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
Surge Voltage test
Leakage Current
Ripple Current Multipliers
120Hz<f<1kHz
0.05
1kHz<f<10kHz 10kHz<f<100kHz 100kHz<f<500kHz
0.3
0.7
1.0
D+0.5
S+0.5
5
2
6.3
2.5
8
10
3.5
5.0
0.5 L<7mm)
0.6( L>7mm)
0.45 L<6mm)
0.6( L>6mm)
d
0.6
0.6
L1=L+1.0 mm MAX L<11mm
L1=L+1.5 mm MAX, L>11 mm
Oct-21