ZWS-BP Series
150W to 480W Single Output Power Supplies
Features
u Universal Input (85 - 265VAC)
u Power factor Corrected
u Up to 200% Peak Power capability
u Five year warranty
u Less than 0.5mA earth leakage current
Key Market Segments & Applications
Specifications
Model
ZWS150BP
ZWS240BP
Input Voltage
Input Current
Inrush Current
Power Factor
Leakage Current
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Efficiency
V
A
A
85-265VAC (47-63Hz), 120-370VDC (Derate to 80% load below 90VAC Input)
1.9 / 0.95
14 / 28
2.8 / 1.5
15 / 30
(1)(2)
(3)
V
0.98 at 100VAC, 0.93 at 200VAC, Meets EN61000-3-2
0.5mA Max. Typically 0.2mA (100VAC), 0.4mA (230VAC)
<0.02%/°C
>101% of peak current capability (constant current style)
24V: 27.6-32.4V, 36V: 41.4-48.6, 48V: 55.2-64.8V
20
mA
%/°C
-
V
ms
%
(1)
(1)
87 / 90%
88 / 91%
Remote On/Off
Optional, contact factory
Line Regulation
Load Regulation
Ripple & Noise
%
%
%
0.4%
0.8%
1%
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
°C
°C
%RH
-10°C to +70°C, derate linearly to 50% load from 50°C to 70°C
-30 to +75°C
Operating: 30 - 90%RH, Storage: 10 - 90%RH
Convection
Withstand Voltage
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
Output to Ground 500VAC (20mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour each
< 196.1 m/s2
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Certifications
Conducted & Radiated EMI
Immunity
UL60950-1, CSA60950-1, EN60950-1, EN50178 OV II, CE Mark
EN55011/EN55022-B, FCC Class B, VCCI-B
EN61000-4-2 (lvl2, 3), -3 (lvl 3), -4 (lvl 3), -5 (lvl 3, 4), -6 (lvl 3), -8 (lvl 4), -11
Weight (Typ)
g
360g
520g
Size (WxHxD)
Warranty
in(mm)
yrs
2.95 x 1.46 x 6.3 (75 x 37 x 160)
3.31 x 1.65 x 7.09 (84 x 42 x 180)
Five Years
Notes:
(1) 100/200VAC
(2) 25°C ambient (cold start)
(3) Avoid prolonged operation in overload
1-800-526-2324 • www.us.tdk-lambda.com/lp/
117
Disclaimer: us.tdk-lambda.com/lp/legal.htm