(888) IPD-CONVerters
ꢀ
(888) 473-2668
ꢀ
www.ipdconverters.com
XWD SERIES - DUAL OUTPUT, 180 WATT
DESCRIPTION
FEATURES
XWD dual output, DC to DC converters are high
powered converters that cover a wide range of
applications. Available input voltages include 12V,
24V, 40V, and 48V. Output voltages are available
from 5V to 15V. The XWD features remote sense
leads for accurate point of load regulation, and has
short circuit and overcurrent protection. For single
and triple output high power solutions, see the XWS
and XWT series of converters.
• High Power Package
• Wide Input Range
• Trim and Enable
• Remote Sense Pins
• 500V Isolation
• Short Circuit
Protection
Efficiency vs. Load (24V Input)
90
85
80
75
70
65
XWD2405
(18v)
(24v)
(36v)
TECHNICAL SPECIFICATIONS
Input
10
20
30
40
50
60
70
80
90 100
Voltage Range
12 VDC Nominal
24 VDC Nominal
48 VDC Nominal
LOAD %
10 - 20 VDC
18 - 36 VDC
36 - 72 VDC
20 - 60 VDC
40 VDC Nominal (Wide Input)
Input Ripple Current
20% Iin Max.
Efficiency vs. Load (48V Input)
Reverse Input Current
100% Iin Max.
90
85
80
75
70
Output
Setpoint Accuracy
±1%
±1% Vout
±1% Vout
10 %
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
XWD4812
XWD4815
Dynamic Regulation, Loadstep
25% Iout
Pk Deviation
Settling Time
Voltage Trim Range
4% Vout
500 µs
±10%
Current Limit Threshold Range, % of Iout Rated
110 - 130%
10
20
30
40
50
60
70
80
90 100
General
LOAD %
Turn-On Time
10 ms
Positive Logic
200 kHz
Remote Shutdown
Switching Frequency
Isolation
Input - Output
500 VDC
±0.02%/°C
Notes
Temperature Coefficient
Case Temperature
Operating Range
† MTBF predictions may vary slightly from model to model.
†† Industrial temp range of -40 to +85°C available.
-25 To +85°C††
-40 To +125°C
105 - 115°C
95%
5 g, 10 - 55 Hz
Consult Factory
Consult Factory
15.4 oz
Storage Range
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Thermal Shutdown Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Weight (Approx.)
1