Pre-amplified/5V Excitation/Gauge
XFPN,XFGN-6 Data sheet
Features
Volt level output
On-chip amplification and temperature compensations
Pre-calibration of offset voltage and span
Applications
.
.
.
.
.
.
.
Non-Invasive Blood Pressure(NIBP)monitor for home health care
Vacuum cleaner
Washing machine
Surface mount package (XFGN)
Part number for ordering
XFGN - 6 025KP G S R
Terminal leads direction (See Outline Diagram)
No mark :
Rated pressure (Pa)
Model
XFPN
XFGN
R
:
Length of the pressure
port
Terminal leads configuration
No mark : DIP (XFPN)
S : Surface mount package (XFGN)
(XFGN only)
6 : 6mm
Pressure type
: Gauge (Positive pressure)
GV : Gauge (Negative pressure)
G
Pressure type
Gauge pressure
XFPN
XFGN-6
Model
Package configuration
Dual-In-line-Package (DIP)
Surface mount package,6mm pressure port
Measurable pressure range (kPa)
Part number for ordering
0
0
24.5
100
25
50
100
200
XFPN-03PGV
XFPN-03PGVR
XFPN-100KPGVR
XFPN-025KPGR
XFPN-050KPGR
XFPN-100KPGR
XFPN-200KPGR
XFGN-603PGVSR
XFGN-6100KPGVSR
XFGN-6025KPGSR
XFGN-6050KPGSR
XFGN-6100KPGSR
XFGN-6200KPGSR
XFPN-100KPGV
XFPN-025KPG
XFPN-050KPG
XFPN-100KPG
XFPN-200KPG
0
0
0
0
Specifications
Model/Rated pressure
03PGV
100KPGV
025KPG
050KPG
100KPG
200KPG
Unit
Recommended operating conditions
Pressure type
Gauge pressure
24.5
0.250
100
1.020
25
0.255
50
1.020
100
1.020
200
2.040
kPa
Rated pressure
kg/cm2
Pressure media
Excitation voltage
Non-corrosive gas
0.25
5
VDC
VDC
Absolute maximum rating
Maximum load pressure
Maximum excitation voltage
Operating temperature
Storage temperature
Operating humidity
Twice of rated pressure
8
10 80
20 100
30 80 (No dew condensation)
RH
mA
Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25
)
Current consumption
Output impedance
Source current
less than 10
less than 10
less than 0.2
less than 2
2 (For the reference)
4.0
mA
mA
msec
V
V
V
Sink current
Mechanical response time
Full scale span voltage
Offset voltage
Full scale span voltage
Accuracy
0.5 0.1
4.5 0.1
5.0
FS/0 50
Note ; Excluding input voltage error.
1