WCMA1008U1X
DC Voltage Applied to Outputs
Maximum Ratings
in High Z State[1]........................................0.5V to VCC + 0.5V
DC Input Voltage[1]..................................–0.5V to VCC + 0.5V
Output Current into Outputs (LOW)............................20 mA
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature .................................–65°C to +150°C
Static Discharge Voltage ..........................................>2001V
(per MIL-STD-883, Method 3015)
Ambient Temperature with
Power Applied...............................................55°C to +125°C
Latch-Up Current ......................................................>200 mA
Supply Voltage to Ground Potential..... ..........–0.5V to +4.6V
Operating Range
Product
Range
Ambient Temperature
VCC
WCMA1008U1X
Industrial
–40°C to +85°C
2.7V to 3.6V
Product Portfolio
Power Dissipation (Industrial)
VCC Range
Operating, ICC
f = fmax
Standby (ISB2
)
Product
Speed
Typ.[2]
Max.
Min.
Typ.[2]
Max.
Typ.[2]
Max.
70 ns
55 ns
WCMA1008U1X
2.7V
3.0V
3.6V
20 mA
40 mA
0.4 µA
30 µA
Notes:
1.
VIL(min.) = –2.0V for pulse durations less than 20 ns.
2. Typical values are included for reference only and are not guaranteed or tested. Typical values are measured at VCC = VCC(typ.), TA = 25°C.
2