10. Reliability Performance
Test Item
Accept criteria
Test Condition
Standard Source
1000 hrs. at rated operating temperature (e.g.
125°C part can be stored for 1000 hrs. @ 125°C.
Same applies for 105°C and 85°C. Unpowered.
Measurement at 24±4 hours after test conclusion.
1.Change from an initial
value L:within±5%
2.no visible damage.
High Temperature
Exposure (Storage)
AEC-Q200 RevD
Table 5
1000 cycles (-40°C to +125°C). Note: If 85°C part or
105°C part the 1000 cycles will be at that
temperature. Measurement at 24±4 hours after
test conclusion. 30min maximum dwell time at
each temperature extreme. 1 min. maximum
transition time.
1.Change from an initial
value L:within±5%
2.no visible damage.
AEC-Q200 RevD
Table 5
Temperature Cycling
1.Change from an initial
value L:within±5%
2.no visible damage.
1000 hours 85°C/85%RH. Unpowered.
Measurement at 24±4 hours after test conclusion. Table 5
AEC-Q200 RevD
Biased Humidity
Operational Life
1.Change from an initial 1000 hrs. @ 105°C. If 85°C or 125°C part will be
value L:within±5%
2.no visible damage.
AEC-Q200 RevD
Table 5
tested at that temperature. Measurement at 24±4
hours after test conclusion.
1.Change from an initial
value L:within±5%
2.no visible damage.
MIL-STD-202
Method 213
Condition C
Peak Value: 100g’s, Duration: 6ms, Waveform:
Half-sine Velocity Change: 12.3ft/sec.
Mechanical Shock
Vibration
5g's for 20 minutes, 12 cycles each of 3
orientations.
Note: Use 8"X5" PCB, .031" thick, 7 secure points
1.Change from an initial
value L:within±5%
2.no visible damage.
AEC-Q200 RevD
on one long side and 2 secure points at corners of Table 5
opposite sides. Parts mounted within 2" from any
secure point. Test from 10-2000 Hz.
Condition K: Reflow temp:250±5℃,
Peak time: 30±5sec, Temp ramp: 1°C/s-4°C/s; time
above 183°C, 90 s - 120 s, Cycles: 3.
Resistance to
Soldering Heat
MIL-STD-202
Method 210
1.no visible damage.
1.Change from an initial
value L:within±5%
2.no visible damage.
AEC-Q200-002
Or
ISO/DIS10605
Passive Component Human Body Model (HBM)
direct contact discharge 8KV.
ESD
1. Lead must have 95%
above coverage.
AEC-Q200 RevD
Table 5
SMD: a) Method B, 4hrs@155℃ dry heat, @235℃
Solder ability
Flammability
1.Meet UL-94 V0 or V1
request
V-0 or V-1 Acceptable.
UL-94
1.Change from an initial 100mmX40mm board mechanical means to apply
Board Flex
value L:within±5%
a force which will bend the board (D) x = 2 mm
AEC-Q200-005
AEC-Q200-006
2.no visible damage.
minimum, applied forces shall be 60 (+ 5) Sec.
Terminal Strenh
(SMD)
1.Component can’t drop
2.no visible damage.
1.8Kg force, applied for 60 second.
Page 8 of 8