5秒后页面跳转
W2CE-1D3-R2/Q PDF预览

W2CE-1D3-R2/Q

更新时间: 2024-11-13 01:46:23
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
3页 109K
描述
Space-saving Dual Output Signal Conditioners Mini-MW Series

W2CE-1D3-R2/Q 数据手册

 浏览型号W2CE-1D3-R2/Q的Datasheet PDF文件第2页浏览型号W2CE-1D3-R2/Q的Datasheet PDF文件第3页 
MODEL: W2CE  
Space-saving Dual Output Signal Conditioners  
[2] OUTPUT 1  
Current  
Mini-MW Series  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
CT TRANSMITTER  
(RMS sensing)  
Functions & Features  
• Converts alternating current from a current transformer  
into a standard process signal  
• Minimum ripple  
• Rerouted input signal does not pass through the base  
socket in order to protect it from melting caused by rush  
current of a motor  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• CT Protector provided for open-circuit protection  
Typical Applications  
• Centralized monitoring and control of motors, pumps or  
heaters by DCS  
• Monitoring power line and power supply current  
29.5 (1.16)  
[3] OUTPUT 2  
Y: None  
Current  
Model  
A: 4 – 20 mA DC (Load resistance 350 Ω max.)  
B: 2 – 10 mA DC (Load resistance 700 Ω max.)  
C: 1 – 5 mA DC (Load resistance 1400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 350 Ω max.)  
E: 0 – 16 mA DC(Load resistance 430 Ω max.)  
F: 0 – 10 mA DC (Load resistance 700 Ω max.)  
G: 0 – 1 mA DC (Load resistance 7000 Ω max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
88.5  
(3.48)  
ZERO  
SPAN  
ZERO  
SPAN  
124  
(4.88)  
mm (inch)  
MODEL: W2CE–[1][2][3]-[4][5]  
Same range availability as Output 1  
ORDERING INFORMATION  
• Code number: W2CE-[1][2][3]-[4][5]  
Specify a code from below for each [1] through [5].  
(e.g. W2CE-5AA-M2/CE/Q)  
[4] POWER INPUT  
AC Power  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
47 – 66 Hz)  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
(90 – 264 V for UL)  
DC Power  
R: 24 V DC  
Note: If one of the outputs should be a current range,  
specify it for the Output 1 to allow a greater load.  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
R2: 11 – 27 V DC  
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
P: 110 V DC  
[1] INPUT  
Current  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
(110 V ±10 % for UL)  
1: 0 – 1 A AC  
5: 0 – 5 A AC  
W2CE SPECIFICATIONS  
ES-5505 Rev.7 Page 1/3  
http://www.m-system.co.jp/  

与W2CE-1D3-R2/Q相关器件

型号 品牌 获取价格 描述 数据表
W2CE-1D3-R2/UL MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series
W2CE-1D4-M2 MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series
W2CE-1D4-M2/CE MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series
W2CE-1D4-M2/N MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series
W2CE-1D4-M2/Q MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series
W2CE-1D4-M2/UL MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series
W2CE-1D4-P MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series
W2CE-1D4-P/CE MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series
W2CE-1D4-P/N MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series
W2CE-1D4-P/Q MSYSTEM

获取价格

Space-saving Dual Output Signal Conditioners Mini-MW Series