Catalog 1308242  
Issued 3-03 (PDF Rev. 11-15)  
Potter & Brumfield  
W28 series  
Push to Reset  
Fuseholder-Type  
Thermal P&B Circuit Breaker  
Note: VDE not available on 16A and 20A W28 only.  
Resettable Overload Capacity: Six times rated current for 0.25 through  
2 amp models. Ten times rated current  
Features  
• Push to reset.  
for 3 through 20 amp models.  
• Approved to many international standards.  
• Replaces slow blow glass cartridge fuse.  
• Labor-saving snap-in mounting.  
• Button extends for visual trip indication.  
Reset Time: 180 seconds max. for 0.25 through 2 amp models. 5 to 30  
seconds for 3 through 20 amp models.  
Agency Approvals  
Typical Resistance vs. Current Rating @ +25°C  
W28 series is UL 1077 Recognized as Supplementary Protectors, File E69543,  
and CSA Accepted as Supplementary Protectors (Appliance Component  
Protectors), File LR15734. W28 breakers are VDE approved for use in office  
equipment (AC loads only) and provides 8mm isolation. 16 amp and 20 amp  
models do not have VDE approvals at present. CCC mark compliant, certificate  
2004010307135992.  
Current  
Rating  
in Amps  
Typical  
Resistance  
in Ohms  
Current  
Rating  
in Amps  
Typical  
Resistance  
in Ohms  
0.25  
0.50  
0.75  
1.0  
2.0  
3.0  
4.0  
5.0  
6.0  
7.0  
14.0  
3.55  
2.0  
0.89  
8.0  
9.0  
0.016  
0.014  
0.011  
0.01  
0.009  
0.009  
0.007  
0.007  
0.007  
0.006  
10.0  
11.0  
12.0  
13.0  
14.0  
15.0  
16.0  
20.0  
Users should thoroughly review the technical data before selecting a product part  
number. It is recommended that users also seek out the pertinent approvals files  
of the agencies/laboratories and review them to confirm the product meets the  
requirements for a given application.  
0.17  
0.069  
0.043  
0.030  
0.026  
0.017  
Electrical Data @ 25°C  
Calibration: Will continuously carry 100% of rating.  
3-20 amp models – may trip between 101% and 134%, but  
must trip at 135% of rating within one hour at +25°C.  
0.25-2 amp models – may trip between 101% and 174%, but  
must trip at 175% of rating within one hour at +25°C.  
Dielectric Strength: Over 1,500 volts RMS.  
Maximum Operating Voltages: 32VDC; 250VAC, 50/60 Hz.  
Interrupt Capacity: 1,000 amps at 250VAC, 50/60 Hz. and 32VDC in  
accordance with UL standard 1077.  
Mechanical/Environmental Data  
Termination: .250” (6.35mm) quick connects. Soldering to terminals is  
not recommended.  
Mounting: Snaps into panel from front. See Recommended  
Panel Cutouts.  
Approximate Weight: 0.35 oz. (10g).  
Ambient Compensation Chart  
Time vs. Current Trip Curve @ +25°C  
1000  
1.40  
(A) All 3-20 Amp Models (B) All 0.25-2 Amp Models  
1.30  
1.20  
1.10  
1.00  
0.90  
0.80  
0.70  
0.60  
Overload  
Trip Times  
Overload  
Trip Times  
900  
800  
700  
600  
500  
400  
300  
200  
100  
0
100%  
135%  
200%  
400%  
600%  
800%  
1000%  
No Trip  
Trip in 1 hour  
2.2-15.0 Sec.  
0.55-1.8 Sec.  
0.27-0.7 Sec.  
0.17-0.45 Sec.  
0.12-0.3 Sec.  
100%  
175%  
200%  
400%  
600%  
No Trip  
Trip in 1 hour  
4.5-28.0 Sec.  
1.0-6.5 Sec.  
0.4-4.0 Sec.  
(A)  
–20 –10 0 10 20 30 40 50 60  
(B)  
AmbientTemperatureInDegreesCentigrade(°C)  
To use this chart: Read up from the ambient tem-  
perature to the curve, and across to find a correction  
factor. Multiply the breaker rating by the correc-  
tion factor to determine the compensated rating.  
Calculate the overloads in terms of the compensated  
rating to use the published trip curve.  
175  
135  
.1  
1
10  
Time In Seconds  
100  
1000  
Do not use these devices outside their specified  
operating temperature ranges.  
Revised 11-15  
www.te.com  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Dimensions are shown for reference  
purposes only. Specifications and avail-  
ability subject to change.  
South America: 55-11-2103-6000  
Hong Kong: 852-2735-1628  
Japan: 81-44-844-8013  
USA: 1-800-522-6752  
Canada: 1-905-470-4425  
Mexico: 01-800-733-8926  
C. America: 52-55-1106-0803  
110  
UK: 44-8706-080208  

与W28-XQ1A-2相关器件

型号 品牌 获取价格 描述 数据表
W28-XQ1A-20 MACOM

获取价格

Push to Reset Fuseholder-Type Thermal P&B Circuit Breaker
W28-XQ1A-20 TE

获取价格

Approved to many international standards
W28-XQ1A-3 MACOM

获取价格

Push to Reset Fuseholder-Type Thermal P&B Circuit Breaker
W28-XQ1A-3 TE

获取价格

Approved to many international standards
W28-XQ1A-4 MACOM

获取价格

Push to Reset Fuseholder-Type Thermal P&B Circuit Breaker
W28-XQ1A-4 TE

获取价格

Approved to many international standards
W28-XQ1A-5 MACOM

获取价格

Push to Reset Fuseholder-Type Thermal P&B Circuit Breaker
W28-XQ1A-5 TE

获取价格

Approved to many international standards
W28-XQ1A-6 MACOM

获取价格

Push to Reset Fuseholder-Type Thermal P&B Circuit Breaker
W28-XQ1A-6 TE

获取价格

Approved to many international standards